SECTION 5
REMOTE OPERATION
5.4.1 OUTPUT PARAMETERS (cont)
:[SOURce:]FREQuency <n>
:[SOURce:]CURRent:LIMit <n> sets Output Current Limit.
:[SOURce:]PHASe2 <n>
:[SOURce:]PHASe3 <n>
:[SOURce:]WAVEFORM <n>
:[SOURce:]WAVEFORM1 <n> sets Output Waveform ΦA.
:[SOURce:]WAVEFORM2 <n> sets Output Waveform ΦB.
:[SOURce:]WAVEFORM3 <n> sets Output Waveform ΦC.
:[SOURce:]RAMP <t>
:[SOURce:]FREQuency:LIMit:MAXimum <n> sets Output Frequency max limit.
:[SOURce:]FREQuency:LIMit:MINimum <n> sets Output Frequency min limit.
:[SOURce:]VOLTage:LIMit:MAXimum <n> sets Output Voltage max limit.
:[SOURce:]VOLTage:LIMit:MINimum <n> sets Output Frequency min limit.
:[SOURce:]VOLTage:INITial <b> sets initial output voltage at power up.
:[SOURce:]RANGe <n>
sets Output Frequency. Range of n is <:SOUR:FREQ:LIM:MIN> to
<:SOUR:FREQ:LIM:MAX> Hz. For convenience, another query for
programmed Frequency is available via the :MEASure:FREQuency?
command. The returned value is an indicator of the set value only as
the UPC does not actually measure Frequency.
n = <0> to <Current meter range> RMS Amps
sets Output Φ angle B.
n = <0> to <359> degrees
sets Output Φ angle C.
n = <0> to <359> degrees
sets Output Waveform.
n = <1> to <16>
n = <1> to <16>
n = <1> to <16>
n = <1> to <16>
sets Output TRANSITION TIME of voltage and frequency execution.
t = <0> to <300> seconds in increments as small as .0002 Sec
n = <20.00> to <5000> Hz
n = <20.00> to <5000> Hz
n = <0.0> to <600> VAC RMS
n = <0.0> to <600> VAC RMS
b = <0> (0 volts) or <1> (last executed)
sets Output Range Control (for power sources that support Range
Control).
n = <0> to <4>. A value of 0 sets the Range Control mode to AUTO.
See section on GENERAL SETUP for more info
84