SECTION 5
REMOTE OPERATION
5.7.3 EXAMPLE OF EXECUTING A STORED PROGRAM
:PROGram:NAME 1 <eos>
:PROGram:EXECute <eos>
5.7.4 EXAMPLE OF EXECUTING A STORED PROGRAM TRANSIENT
:PROGram:NAME 1 <eos>
:PROGram:EXECute <eos>
:PROGram:EXECute:TRANS <eos>
5.7.5 EXAMPLE OF DIRECTLY CHANGING THE OUTPUT PARAMETERS
Change Frequency and Volts for all phases then ENABLEs the OUTPUT.
:FREQuency 50 <eos> Step B. Change Frequency to 50 Hz.
:VOLTage 117 <eos>
:OUTPut ON <eos>
An alternative to steps B, C and D above is:
:FREQ 50; :VOLT 117; :OUT ON<eos> This example uses all shortform keywords in one Program
- or -
:OUTPut OFF <eos>
Step A. Address the UPC as a listener.
Step B. Select Program 1.
NOTE: <eos> is a LINE FEED (0Ahex, 10dec)
Step C. Execute Program.
Step D. Un-address UPC.
Step A. Address the UPC as a listener.
Step B. Select Program 1 for executing.
NOTE: <eos> is a LINE FEED (0Ahex, 10dec).
Step C. Execute Program.
Step D. Execute Transient.
Step E. Un-address UPC.
Step A. Address the UPC as a listener.
Step C. Change Volts to 117 VAC RMS for all phases.
Step D. ENABLES the OUTPUT. The OUTPUT POWER switch must
be in the ON/AUTO position to allow power to be applied to the load.
Step E. Un-address UPC.
Message. The OUTPUT POWER switch must be in the ON/AUTO
position to allow power to be applied to the load.
Turns the output OFF.