5.3.1 STEADY-STATE OUTPUT PARAMETERS

FORM,<n>
COUPLing,<s>
XFMRRATIO,<n.nn>
FREQuency,<n>
VOLTage,<n>
VOLTage1,<n>
VOLTage2,<n>
VOLTage3,<n>
CURRent:LIMit, <n>
PHASe2,<n>
PHASe3,<n>
WAVEFORM,<n>
WAVEFORM1,<n>
WAVEFORM2,<n>
WAVEFORM3,<n>
EVENTS <n>
sets Output Power Form of selected program.
n = <1>Single Φ, <2>Split Φ, or <3>Three Φ
sets Output coupling of selected program.
s = <DIRECT> or <XFMR>
sets Output XFMR ratio (n.nn:1) of selected program.
n.nn = <0.01> to <5.11>
sets Output Frequency of selected program.
n = <:SOUR:FREQ:LIM:MIN> to <:SOUR:FREQ:LIM:MAX> Hz
sets Output VOLTAGE ΦA,B,C of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets Output VOLTAGE ΦA of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets Output VOLTAGE ΦB of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets Output VOLTAGE ΦC of selected program.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets Output Current Limit of selected program.
n = <0> to <AMPS meter range> Amps
sets Output Φ angle B of selected program.
n = <0> to <359> degrees
sets Output Φ angle C of selected program.
n = <0> to <359> degrees
sets Output Waveform ΦA, ΦB, ΦC of selected program.
n = <1> to <16>
sets Output Waveform ΦA of selected program.
n = <1> to <16>
sets Output Waveform ΦB of selected program.
n = <1> to <16>
sets Output Waveform ΦC of selected program.
n = <1> to <16>
sets number of times to repeat the transient portion of the selected
program when the Transient is executed.
n = 0-65535. A value of 0 specifies continuous operation.