Transient Segment Parameters - Pacific UPC-32 Operation Manual

Table of Contents

Advertisement

SECTION 5
REMOTE OPERATION

5.3.2 TRANSIENT SEGMENT PARAMETERS

SEGment,<n>
FSEG,<n>
VSEG,<n>
VSEG1,<n>
VSEG2,<n>
VSEG3,<n>
WFSEG,<n>
WFSEG1,<n>
WFSEG2,<n>
WFSEG3,<n>
TSEG,<n>
LAST
selects transient segment n of the presently selected program to be
edited.
n = <1> to <100>
sets objective Frequency of selected segment.
n = <:SOUR:FREQ:LIM:MIN> to <:SOUR:FREQ:LIM:MAX> Hz.
sets objective voltage ΦA, ΦB, ΦC of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets objective voltage ΦA of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets objective voltage ΦB of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets objective voltage ΦC of selected segment.
n = <0> to <150, or 150 x XFMRRATIO> Volts
sets Waveform ΦA, ΦB, ΦC of selected segment.
n = <1> to <16>
sets Waveform ΦA of selected segment.
n = <1> to <16>
sets Waveform ΦB of selected segment.
n = <1> to <16>
sets Waveform ΦC of selected segment.
n = <1> to <16>
sets execution time (to reach objective Voltage and Frequency) of
selected segment.
n = <0> or <.0002> to <300> seconds. Setting n to <0> selects cycle-
based transient operation, i.e., each segment time is equal to the
period of 1 cycle (1/FREQ)
sets selected segment to be the last segment of selected transient.
82