SECTION 5
REMOTE OPERATION
5.5.2 METERED DATA QUERIES (cont)
:MEASure:FREQuency?
:MEASure:CURRent[:RMS]1? Query: metered RMS current ΦA.
:MEASure:CURRent[:RMS]2? Query: metered RMS current ΦB.
:MEASure:CURRent[:RMS]3? Query: metered RMS current ΦC.
:MEASure:CURRent:PEAK1? Query: metered peak current ΦA.
:MEASure:CURRent:PEAK2? Query: metered peak current ΦB.
:MEASure:CURRent:PEAK3? Query: metered peak current ΦC.
:MEASure:CURRent:CREST1? Query: metered current Crest Factor ΦA.
:MEASure:CURRent:CREST2? Query: metered current Crest Factor ΦB.
:MEASure:CURRent:CREST3? Query: metered current Crest Factor ΦC.
:MEASure:POWer1?
:MEASure:POWer2?
:MEASure:POWer3?
:MEASure:KVA1?
:MEASure:KVA2?
:MEASure:KVA3?
Query: for programmed Frequency. The returned value is only
an indicator of the programmed Frequency as the UPC does not
actually measure Frequency.
Returns <20.00> to <5000> Hz
Returns <0> to <current meter range> AAC RMS
Returns <0> to <current meter range> AAC RMS
Returns <0> to <current meter range> AAC RMS
Returns <0> to <current meter range> AAC Peak
Returns <0> to <current meter range> AAC Peak
Returns <0> to <current meter range> AAC Peak
Returns <0> to <1000>
Returns <0> to <1000>
Returns <0> to <1000>
Query: metered Kilowatts ΦA.
Returns <0> to <1000> KW
Query: metered Kilowatts ΦB.
Returns <0> to <1000> KW
Query: metered Kilowatts ΦC.
Returns <0> to <1000> KW
Query: metered KiloVoltAmps ΦA.
Returns <0> to <1000> KVA
Query: metered KiloVoltAmps ΦB.
Returns <0> to <1000> KVA
Query: metered KiloVoltAmps ΦC.
Returns <0> to <1000> KVA