SECTION 4
OPERATION
4.5.2.2 CYCLE BASED TRANSIENT EXAMPLE (cont)
Press 15, ENTER, 15, ENTER, 15, to select waveform #15 on all three phases.
TRANSIENT: PRGM #4
T=1 CYCLE
F=400
Press STORE, to save the transient sequence.
TRANSIENT EVENTS:
ENTER # OF TRANSIENT EVENTS 1
0 FOR INFINITE OR 1-65535.
Press 1, STORE, to cause only one transient event.
V/I METER:
FREQ=400.0
SENSE=INT
MANUAL MODE Ia=00.0
If the UPC was previously executing program #4, it will now be in MANUAL MODE. This is because
program #4 has changed. To execute the transient you must first execute program #4. Press
PROGRAM, 4, ENTER, EXECUTE, to execute the program.
V/I METER:
FREQ=400.0
SENSE=INT
PROGRAM #4
Press TRANS to execute the transient.
This cycle based transient will switch waveform #15 in for one cycle. This will cause a spike on the
positive and negative half of the sine wave for one cycle. See figure 4.5.2.2.
SEGMENT #1
Va=122
Vb=122
WFa=15
WFb=15
Va=108.0
Vb=108.0
Vab=187.1 Vbc=187.1 Vca=187.1
Ib=00.0
Va=108.0
Vb=108.0
Vab=187.1 Vbc=187.1 Vca=187.1
Ia=00.0
Ib=00.0
58
OF 1
Vc=122
WFc=15
Vc=108.0
Ic=00.0
Vc=108.0
Ic=00.0