4.5.2.1 TIME BASED TRANSIENT EXAMPLE (cont)
Press 1, ENTER, 1, ENTER, 1, to select WaveForm 1 on all three phases.
TRANSIENT: PRGM #4
T=0.01
F=400
Press ENTER, now we are starting segment 3 of 3.
TRANSIENT: PRGM #4
T=0.01
F=400
Press ENTER, ENTER, .07, ENTER, to select default segment 3 of 3 and a time 70 milliseconds.
TRANSIENT: PRGM #4
T=.07
F=400
Press 108, ENTER, 108, ENTER, 108, ENTER, to select 108 volts on all three phases.
TRANSIENT: PRGM #4
T=0.07
F=400
Press 400, ENTER, to select 400 Hz..
TRANSIENT: PRGM #4
T=0.07
F=400
SEGMENT #2
Va=80
Vb=80
WFa=1
WFb=1
SEGMENT #3
Va=108
Vb=108
WFa=1
WFb=1
SEGMENT #3
Va=108
Vb=108
WFa=1
WFb=1
SEGMENT #3
Va=108
Vb=108
WFa=1
WFb=1
SEGMENT #3
Va=108
Vb=108
WFa=1
WFb=1
55
SECTION 4
OF 2
Vc=80
WFc=1
OF 3
Vc=108
WFc=1
OF 3
Vc=108
WFc=1
OF 3
Vc=108
WFc=1
OF 3
Vc=108
WFc=1
OPERATION