Pacific UPC-32 Operation Manual page 73

Table of Contents

Advertisement

4.6.1.1 COPY PROGRAM
COPY PROGRAM is used to copy Program data.
From any METER display (V/I, AMPS or POWER), press the fn key to enter SETUP MODE.
From the SETUP display, press 1 to enter PROGRAM SETUP.
From the PROGRAM SETUP display, press 1 to enter COPY PROGRAM.
COPY PROGRAM:
SOURCE PROGRAM NUMBER=1
DESTINATION PROGRAM NUMBER=2
PRESS STORE TO COPY.
SOURCE PROGRAM NUMBER:
0 will copy the present MANUAL MODE operating parameters.
1-99 are user created programs that may be edited or copied to and from.
Program 100 is a MIL-STD-704D overvoltage transient.
Program 101 is a MIL-STD-704D undervoltage transient.
Program 102 is a MIL-STD-704D over-frequency transient.
Program 103 is a MIL-STD-704D under-frequency transient.
These programs may be copied to any of programs 1 - 99 and executed.
DESTINATION PROGRAM NUMBER:
1-99 are user created programs that may be edited or copied to and from.
NOTE: You cannot copy to a program that is currently executing.
4.6.1.2 DELETE PROGRAM
DELETE PROGRAM is used to delete programs. This is useful to free up memory.
From any METER display (V/I, AMPS or POWER), press the fn key to enter SETUP MODE.
From the SETUP display, press 1 to enter PROGRAM SETUP.
From the PROGRAM SETUP display, press 2 to enter DELETE PROGRAM.
DELETE PROGRAM:
PROGRAM TO DELETE=1
PRESS STORE TO ERASE.
NOTE: You cannot delete a program that is currently executing.
RANGE
0-103
1-99
RANGE
1-99
61
SECTION 4
OPERATION

Hide quick links: