Step 7: Saving The Settings - IAI GOX-2402M-USB User Manual

Table of Contents

Advertisement

Adjusting the Black Level
1
Expand [AnalogControl], and select the black level you want to configure in
[BlackLevelSelector].
[DigitalAll] (master black), [DigitalRed]* (digital R), and [DigitalBlue]* (digital B) can
be configured.
2
Specify the adjustment value in [BlackLevel].
*) Color model only

Step 7: Saving the Settings

The setting values configured in the player (eBUS SDK for JAI) will be deleted when the
camera is turned off. By saving current setting values to user memory, you can load and
recall them whenever necessary. You can save up to three sets of user settings in the
camera. (User Set1 to 3)
Note
Changes to settings are not saved to the computer (eBUS SDK for JAI).
■ To save user settings
1
Stop image acquisition.
2
Expand [UserSetControl], and select the save destination ([UserSet1] to
[UserSet3]) in [UserSetSelector].
Note
The factory default setting values are stored in [Default] and cannot be overwritten.
Caution
Settings can only be saved when image acquisition on the camera is stopped.
Memory(Flash)
一時メモリ
DefaultSet
Memory(RAM)
UserSet1
UserSet2
UserSet3
— 21 —
Working Set
eBUS Player for JAI
Go-X Series USB3 Vision I/F
eBUS SDK for
JAI (Player)