The following formula can be used to estimate the focal length.
Focal length = WD /(1 + W/w)
WD :Working distance (distance between lens and object)
W
:Width of object
w
:Width of sensor
② Direct connection(or MP-43 tripod adapter plate)
When mounting the camera directly to a wall or other device, use screws that match the
camera locking screw holes on the camera (M3, depth: 3 mm). Use the supplied screws to
attach the tripod adapter plate.
Caution
For heavy lenses, be sure to support the lens itself. Do not use configurations in which its weight
is supported by the camera.
③ USB cable
Connect a USB cable to the USB 3.0 connector.
Caution
The camera is equipped with a USB 3.0 compatible Micro B connector. Although this connector
includes USB 2.0 connectors, the camera does not support use of USB 2.0.
④ DC IN / trigger IN connection cable
⑤ AC adapter (power supply) (if necessary)
Connect the AC adapter and the round connector of the connection cable to the DC IN /
trigger IN connector on the camera.