ROI Function (Multi ROI)

In the Multi ROI mode, you can specify up to 64 scanning areas for a single-frame image.
The areas cannot overlap.
This function is supported in GOX-3200MC-USB, GOX-5102MC-USB only.
The Multi ROI mode can be used only when both the Sequencer mode and the Shading
mode are off.
Set [MultiROIControl]->[MultiRoiMode] On. Select from the eight indexes in
[MultiRoiIndex] then set [MultiRoiWidth], [MultiRoiHeight], [MultiRoiOffsetX] and
[MultiRoiOffsetY].
And set the index number to be enabled to [MultiRoiVerticalEnable] and
[MultiRoiHorizontalEnable].
■ Example
To use four areas as shown below, refer to the following.
1. Set [MultiROIControl]->[MultiRoiMode] On.
2. Select "0" in [MultiRoiIndex].
Set [MultiRoiWidth], [MultiRoiHeight], [MultiRoiOffsetX] and [MultiRoiOffsetY].
3. Select "1" in [MultiRoiIndex].
Set [MultiRoiWidth], [MultiRoiHeight], [MultiRoiOffsetX] and [MultiRoiOffsetY].
4. Set True to [MultiRoiVerticalEnable[Index2]].
5. Set True to [MultiRoiHorizontalEnable[Index2]].
OffsetY[0]
Height[0]
OffsetY[1]
Height[1]
Output image
OffsetX[0]
OffsetX[1]
JAI
Width[0]
Width[0] + Width[1]
— 49 —
Using areas
(four green areas)
Width[1]
Height[0] + Height[1]
Go-X Series USB3 Vision I/F