Step 5: Changing the Camera Settings

This section explains how to change settings by describing the procedure for changing the
output format as an example.
Configuring the Output Format
Configure the size, position, and pixel format of the images to be acquired.
The factory settings are as follows. Change the settings as necessary.
Factory default values (GOX-3201C-USB)
ImageFormatControl
* You can specify the image acquisition area. For details, see "ROI (Regional Scanning Function)".
1
Configuring the [Width] of[ImageFormatControl]
By selecting the item of [Width], you can change the value as shown below.
Device Control
Visibility
Beginner
DeviceControl
DeviceVendorName
DeviceModelName
DeviceManufactureInfo
DeviceVersion
DeviceFirmwareVersion
DeviceSerialNumber
DeviceUserID
DeviceTemperature
DeviceReset
ImageFormatControl
SensorWidth
SensorHeight
WidthMax
HeightMax
Width
Height
Offset X
Offset Y
ReverseX
ReverseY
PixelFormat
Test Pattern
Acquisition Control
Acquisition
Note
Depending on the setting item, you need to change visibility.
Please switch visibility (Beginner / Expert / Guru) as necessary.
Item
Width
Height
OffsetX (horizontal position)
OffsetY (vertical position)
PixelFormat
JAI Corporation
GOX-3201C-USB
See the possibilities
XXXXX
XXXXX
XXXXX
JAI_DEMO
XXXXX
2048
1536
2048
1536
2048
1536
0
0
False
False
BayerRG8
Off
Continuous
— 18 —
Go-X Series USB3 Vision I/F
Default value
2048
1536
0
0
BayerRG8
×