IAI GOX-2402M-USB User Manual page 31

Table of Contents

Advertisement

■ During Continuous operation ([Frame Start] trigger is [Off])
FR_Cont[Hz] = MIN(Interface_FR, Sensor_FR)
■ When [TriggerMode] is [On] ([Frame Start] trigger is [On])
First, calculate the maximum OverlapTime value for the shortest trigger cycle.
MaxOverlapTime_TrOlrd[us] = (1000000/FR_Cont) - (Non-ExposurePeriod[H] x H_period)
*) Please refer to table below for Non-ExposurePeriod[H] .
Non-ExposurePeriod[H]
Model name
GOX-2402MC-USB
GOX-3200MC-USB
GOX-3201MC-USB
GOX-5102MC-USB
GOX-5103MC-USB
GOX-8901MC-USB
GOX-12401MC-USB
*) In GOX-2402M-USB, When using Binning(2x2) and PixelFormat is Mono8 or Bayer8, Non-ExposurePeriod[H] = 16.
・When ExposureTime ≦ MaxOverlapTime_TrOlrd
FR_TrOlrd[Hz] = FR_Cont
・When ExposureTime > MaxOverlapTime_TrOlrd
Non-OverlapExposureTime_TrOlrd = ExposureTime - MaxOverlapTime_TrOlrd
FR_TrOlrd[Hz] = 1000000/{ (1000000/FR_Cont) + Non-OverlapExposureTime_TrOlrd }
14
16
14
16
14
14
14
(Same as during Continuous operation)
— 31 —
Go-X Series USB3 Vision I/F