Step 5: Adjusting the Image Quality

To maximize the performance of the camera, configure its basic function in the following order.
1
Configure the line rate (exposure time and shutter).
For details on this setting, "Variable Line Rate" (page 33) and "Electronic Shutter" (page 34).
2
Configure the gain.
For details on this setting, see "Gain Control" (page 30).
3
Configure the DSNU and PRNU settings.
For details on this setting, see "DSNU Correction" (page 29) and "PRNU Correction" (page 29).
4
Perform shading correction.
For details on this setting, see "Shading Correction" (page 32).
Caution
Perform black level adjustments and magnification aberration correction after configuring the above settings.

Step 6: Configuring Various Other Settings

See "Settings List" (page 37), and configure settings as necessary.

Step 7: Saving the Settings

The setting values configured in Control Tool will be deleted when the camera is turned off. By storing
current setting values to user memory, you can load and recall them whenever necessary. You can
save up to two sets of user memory settings (User 1 Data and User 2 Data).
Note
The setting values are not saved to the computer (Control Tool).
User memory
Temporary memory
User 1 Data
Save
User 2 Data
̶ 18 ̶
Current
setting
values
WA-1000D-CL
Control
Tool