Timing Chart - IAI GOX-2402M-USB User Manual

Table of Contents

Advertisement

Timing chart

■ When [ExposureMode] is [Timed]
• FrameStartTrigger On
Trigger
Sensor
Exposure
Exposure
Active
Readout
GOX-2402MC-USB
PixelFormat
Binning Off
Mono8
Mono10/Mono12
Mono10p
Mono12p
Bayer8
Bayer10/Bayer12
Bayer10p
Bayer12p
Horizontal Binning On
Mono8
Mono10
Mono10p
Vertical Binning On
Mono8
Mono10
Mono10p
Horizontal Binning On & Vertical Binning On
Mono8
Mono10
Mono10p
A (Frame Period)
B
Exposure time
Frame Period [A] (usec)
— 32 —
Next trigger disabled
Period From Trigger start edge to
6146
12300
7686
9225
6146
12300
7686
9225
5924
7348
7348
5924
7348
7348
2504
3782
3782
Go-X Series USB3 Vision I/F
Next trigger
Input enabled
Exposure start [B] (usec)
15.4
18.8
18.9
18.9
15.4
18.8
18.9
18.9
15.4
18.9
18.9
15.4
18.9
18.9
12.8
18.9
18.9

Advertisement

Table of Contents
loading

Table of Contents