項⽬
m) BlemishControl
BlemishEnable
BlemishDetect
BlemishDetectionResult
BlemishStore
BlemishDetectThreshold
BlemishCompensationIndex
BlemishCompensationPositionX
BlemishCompensationPositionY
BlemishCompensationDataClear
BlemishCompensationNumber
n) SequencerControl
SequencerMode
SequencerModeSelect
SequencerSetSelector
SequencerWidth
SequencerHeight
SequencerOffsetX
SequencerOffsetY
SequencerFrameCount
SequencerExposureTime
SequencerGainAnalogAll
SequencerGainDigitalRed
SequencerGainDigitalBlue
SequencerLutEnable
SequencerSetNext
SequencerRepetition
SequencerSetActive
SequencerSetStart
SequencerCommandIndex
SequencerReset
設定範囲
初期値
True, False
True
1 〜 100
10
1 〜 256
1
-1
-1
0 〜 256
0
0:Off, 1:On
Off
0:TriggerSequencerMode,
TriggerSequencerMode
1:CommandSequencerMode
1〜32
1
1μs 〜
x1.0 〜 x126.0
x1.0
x0.447〜x5.624
x1.0
x0.447〜x5.624
x1.0
True, False
False
0 〜 32
1〜255
1
1〜32
1
1〜32
1
1〜32
1
Configure blemish compensation settings.
Enable/disable blemish correction.
Execute blemish detection.
This command can not be executed under the following conditions.
・When no image is output
・In Sequencer mode
・In single ROI mode
・In Binning mode
Display the blemish detection results.
0:Idle
1:Succeeded
3:Error2 - exceeded max compensation number
4:Error3 - could not detected
5:Error4 - timeout
Save the location information of detected blemishes.
Set the blemish detection threshold.
Select the index for the target blemish coordinates
(BlemishDataPosition X/Y).
Display the X coordinate (horizontal pixel position) of the target blemish
selected in [BlemishCompensationIndex].
You can also manually enter the X coordinate of the blemish you want to correct.
[Setting range]
GOX-2402MC-USB: -1〜1919
GOX-3200MC-USB: -1〜2047
GOX-3201MC-USB: -1〜2047
GOX-5102MC-USB: -1〜2447
GOX-5103MC-USB: -1〜2447
GOX-8901MC-USB: -1〜4095
GOX-12401MC-USB: -1〜4095
Display the Y coordinate (vertical pixel position) of the target blemish selected
in [BlemishCompensationIndex].
You can also manually enter the Y coordinate of the blemish you want to correct.
[Setting range]
GOX-2402MC-USB: -1〜1119
GOX-3200MC-USB: -1〜1535
GOX-3201MC-USB: -1〜1535
GOX-5102MC-USB: -1〜2047
GOX-5103MC-USB: -1〜2047
GOX-8901MC-USB: -1〜2159
GOX-12401MC-USB: -1〜2999
Delete detected or specified blemish information selected in
[BlemishCompensationIndex].
Display the number of target blemishes.
Configure sequencer settings.
Enable/disable [SequencerMode].
Select the sequencer mode.
Select the index number to configure.
Set the width of the selected SequencerIndex.
Set the height of the selected SequencerIndex.
Set the horizontal offset value for the selected SequencerIndex.
Set the vertical offset value for the selected SequencerIndex.
Set the FrameCount value for the selected SequencerIndex.
Set the exposure time for the selected SequencerIndex.
Set the GainAnalogAll value for the selected SequencerIndex.
Set the DigitalRed Gain value for the selected SequencerIndex.
Set the DigitalBlue Gain value for the selected SequencerIndex.
Set the LutEnable value for the selected SequencerIndex.
Set the next index to be displayed for the selected SequencerIndex.
(Enabled only for TriggerSequencer.)
If 0 is specified, the operation of Sequencer is stopped.
Set the repeat count for the sequencer.
Displays the sequencer set number.
Specify the first index number to switch to when starting
[TriggerSequencerMode].
Set this to change the SequencerIndex.
In [TriggerSequencerMode], reset the current index number to the number
configured in [SequencerSetStart].
— 66 —
Go-X Series USB3 Vision I/F
説明
・Outputting TestPattern
・In Overlap MultiRoi mode
・In Decimation mode
・In multi ROI mode
(Enabled only for CommandSequencer.)

Advertisement