IAI GOX-2402M-USB User Manual page 54

Table of Contents

Advertisement

■ Internal camera blocks
Counter0
FrameStartTrigger
Counter1
ExposureStart
Counter2
SensorReadOut
Counter3
FrameTransferEnd
■ To use the counter function
Configure the settings as follows.
Four counters are available. Specify a counter (Counter0 to Counter3), and
configure the settings.
Item
Counter 0 ~ 3
CounterEventSource
CounterEventActivation
Event detection
Event detection
Event detection
At event occurrence or count up
Event detection
At event occurrence or count up
Counter reset
Internal MCU of camera
Setting value /
selectable range
Counter 0 ~ 3
Counter0
Off, FrameStartTrigger
Counter1
Off, ExposureStart
Counter2
Off, SensorReadOut
Counter3
Off, FrameTransferEnd
Rising Edge, Falling Edge
— 54 —
Counter
At event occurrence or count up
Counter
At event occurrence or count up
Counter
Counter
Read requested counter value
Description
Select the counter.
Select the counter event signal
for which to read the count
value.
When set to Off, the counter
operation will stop (but will not
be reset).
Specify timing at which to count.
Counter0 Rising Edge
Counter1 Rising Edge
Counter2 Rising Edge
Counter3 Falling Edge
Go-X Series USB3 Vision I/F
Send information
to the HOST

Advertisement