Table 60: Specific Module / Channel Parameters for 750-652/040-000
GSD File
Description
Parity
Stop bits
Flow control
Continuous
send
Continuous
receive
Switching time
RS-485
Monitoring
time con.
receive
*)
Default setting
con. = continuous
11.1.2.2

PROFIBUS DP Fieldbus Coupler (750-333/040-000)

The aforementioned fieldbus couplers allow module-specific configuration of
behavior at diagnosis.

Table 61: General Module / Channel Parameters

Parameter
Diagnostics channel
x
(x = 0)
*)
Default setting
Manual
Version 1.3.0
750-652/040-000 Serial Interface RS-232/RS-485 XTR
Value
*)
none
odd
straight
*)
1
2
*)
deactivated
XON/XOFF
RTS/CTS
RTS, lead/follow-on time Flow Control
*)
lock
release
*)
lock
release
*)
100 us
2 characters
4 characters
*)
2 characters
4 characters
Value
*)
0 (lock)
1 (release)
WAGO-I/O-SYSTEM 750 XTR
WAGO-I/O-CHECK
Selection box
Parity
Parity
Parity
Stop Bits
Stop Bits
Flow Control
Flow Control
Flow Control
Continuous Send Mode
Continuous Send Mode
Continuous Receive Mode disabled
Continuous Receive Mode release
Switchover Time RS-485
Switchover Time RS-485
Switchover Time RS-485
Continuous Receive
Timeout
Continuous Receive
Timeout
Explanation
The fieldbus coupler signals a diagnosis if the
I/O module reports the event:
Overflow (input buffer)
Diagnostics reported by the I/O module do not
lead to the signaling of a diagnosis by the
fieldbus coupler.
Diagnostics reported by the I/O module lead to
the signaling of a diagnosis by the fieldbus
coupler.
Value
*)
none
odd
straight
*)
1
2
*)
disabled
XON/XOFF
RTS/CTS
RTS, lead/follow-on
time
*)
disabled
release
*)
*)
100 us
2 Characters
4 Characters
*)
2 Characters
4 Characters