D/R,Exp - RadioLink AT9S PRO Manual

Adaptable to helicopter/fixed wing/glider/multirotor/car/boat/robot, dsss&fhss/crsf
Hide thumbs Also See for AT9S PRO:
Table of Contents

Advertisement

Set rate and EXP(Ex: High
rate=95%,0%exponential)
Go to 2nd switch position
and
exponential.
Optional: if using a 3 position
switch, set 3rd rate.
Optional: assign dual rates
to have one for each
condition.
Goals
Set up aileron triple rates on
SWITCH C with travel
settings of 75%(normal)
25%(slow roll)and 140%
(extreme aerobatics)and
exponential setting of
0%, +15%, and -40%
respectively.
NOTE: This normal rate has
no exponential so it has a
Very linear, normal feel.
This is slow roll rate has
positive exponential
(the opposite of what most
people normally uses),
which makes the servos
more responsive around
center.
This
makes
servos feel the same around
center in the normal and low
rates, but still gives a very
slow roll rate at full stick.
3D rate (extreme aerobatics)
has a very high distance of
travel nearly twice that of
the normally rate.
Therefore, using a very high
rate negative exponential
setting
softens
how
servos
responses
around
center stick.
set
rate
and
Steps
Open D/R,EXP
Choose channel to change
(Ex:aileron is already selected)
Optional: Change switch position.
Confirm switch is in desired
position and set rate.(Ex: up=high
rate,75%)
Move Switch to 2nd rate position
and set this particular rate (Ex:
center=low rate,25%)
Optional: If using a 3 position
SW, move SW to 3rd position
and set this rate.(Ex: DOWN=3D
rate, 140%)
Optional: except using a switch,
you can set high rates to be
the
triggered when the stick moves
past a certain point. To test this,
set aileron high rate to 25%.Now
set switch assignment to AIL
(90%). Move AILERON STICK to
the right and notice the huge
jump in travel after the stick
moves 90% of its distance.
the
Set each rate's EXP.
(Ex:0%,+15%,-40%)
to Rate, PUSH.
to 95%,confirm 0% EXP.
to NO,PUSH
to DOWN,PUSH.
to NO,PUSH.
to COND repeat above.
to SW,PUSH.
to COND.
Repeat steps above to adjust for each condition.
Inputs
for 1s to BASIC (
D/R,EXP,PUSH.
to CH,PUSH,
to SW,PUSH
to D/R
AILERON STICK
AILERON STICK
SWC to center position,
AILERON STICK
AILERON STICK
SWC to DOWN position.
AILERON STICK
AILERON STICK
to SWA
to D/R
AILERON STICK
AILERON STICK
AILERON STICK and watch screen
graph. See the change? You may also
change the trigger point by holding the
stick at the desired point then pressing
and holding the PUSH.
to EXP .PUSH
C to UP position confirm EXP reads 0.
C to DOWN position.
AILERON STICK
AILERON STICK
C to center position
Repeat to set low rate EXP to -40%.
22
Radiolink Electronic Ltd
www.radiolink.com
to AILE,PUSH
to SWC,PUSH
C t o UP pos iti on.
to75%.PUSH
to75%.PUSH
to D/R
to 25%,PUSH
to 25%,PUSH
to 140%,PUSH
to 140%,PUSH
to AILE(90%) , PUSH
to 25%
to 25%
to+15% .PUSH
to+15%.PUSH
to

Hide quick links:

Advertisement

Table of Contents
loading