Agilent Technologies U2722A User Manual
Agilent Technologies U2722A User Manual

Agilent Technologies U2722A User Manual

Usb modular source measure units
Hide thumbs Also See for U2722A:
Table of Contents

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies U2722A

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 Agilent U2722A/U2723A USB Modular Source Measure Units User’s Guide Agilent Technologies...
  • Page 3 Notices Warranty Safety Notices © Agilent Technologies, Inc., 2009 - 2011 No part of this manual may be reproduced in The material contained in this docu- any form or by any means (including elec- ment is provided “as is,” and is sub-...
  • Page 4 Caution, risk of danger (refer to this manual Earth (ground) terminal for specific Warning or Caution information) Protective conductor terminal Caution, hot surface Frame or chassis terminal Out position of a bi-stable push control Equipotentiality In position of a bi-stable push control U2722A/U2723A User’s Guide...
  • Page 5 • Always use dry cloth to clean the device. Do not use ethyl alcohol or any other volatile liquid to clean the device. • Do not permit any blockage of the ventilation holes of the device. U2722A/U2723A User’s Guide...
  • Page 6 20% to 85% RH non-condensing Storage temperature –20 °C to 70 °C Storage humidity 5% to 90% RH non-condensing The U2722A/U2723A USB Modular Source Measure Units complies with N O T E the following safety and EMC requirements: • IEC 61326-1:2005/EN61326-1:2006 • Canada: ICES-001:2004 •...
  • Page 7 Cet appareil ISM est confomre a la this electrical or electronic product in norme NMB-001 du Canada. domestic household waste. The CSA mark is a registered trademark of the Canadian Standards Association. U2722A/U2723A User’s Guide...
  • Page 8 “Monitoring and Control Instrument” product. The affixed product label is as shown below. Do not dispose in domestic household waste To return this unwanted instrument, contact your nearest Agilent Technologies, or visit: www.agilent.com/environment/product for more information. U2722A/U2723A User’s Guide...
  • Page 9 In This Guide… Getting Started This chapter provides an overview of the U2722A/U2723A USB Modular Source Measure Units, which includes the product outlook, product dimensions, and product layout. This chapter also contains instructions on how to install and configure the U2722A/U2723A.
  • Page 10 The Declaration of Conformity (DoC) for this instrument is available on the Web site. You can search the DoC by its product model or description. http://regulations.corporate.agilent.com/DoC/search.htm If you are unable to search for the respective DoC, please contact your N O T E local Agilent representative. U2722A/U2723A User’s Guide...
  • Page 11 U2722A/U2723A User’s Guide...
  • Page 12: Table Of Contents

    B. Install the IO Libraries Suite C. Install the module driver D. Install the Agilent Measurement Manager E. Connect the module to your PC F. Verify your module connection G. Launch your Agilent Measurement Manager Instrument Configuration Cable Installation Chassis Installation U2722A/U2723A User’s Guide...
  • Page 13 Memory list commands storing and restoring Memory list delay setup Memory list commands execution Memory list commands execution state Characteristics and Specifications Product Characteristics Product Specifications Appendixes Appendix A: List of Self-Test Return Codes Appendix B: Time-out Settings U2722A/U2723A User’s Guide...
  • Page 14 Remote sense connection Figure 2-11 Guarded connection Figure 2-12 Commands that control measurement time Figure 2-13 U2722A/U2723A outputs connected in series Figure 2-14 U2722A/U2723A outputs connected in parallel Figure 2-15 Channel state and Status Operation Condition register bit for external trigger...
  • Page 15 List of Figures U2722A/U2723A User’s Guide...
  • Page 16 Table 2-1 Type of commands that can be saved into the memory list Table 2-2 Time delay set for each range when auto delay is enabled Table 4-1 List of system-related return codes Table 4-2 Time-out settings U2722A/U2723A User’s Guide...
  • Page 17 List of Tables U2722A/U2723A User’s Guide...
  • Page 18: Getting Started

    Instrument Configuration Cable Installation Chassis Installation This chapter provides an overview of the U2722A/U2723A USB Modular Source Measure Units, which includes the product outlook, product dimensions, and product layout. This chapter also contains instructions on how to install and configure the U2722A/U2723A.
  • Page 19: Introduction

    U2722A/U2723A has three outputs. The voltage range is –20 V to 20 V, whereas the maximum current output per channel is 120 mA. The U2722A/U2723A is controlled remotely over a USB interface via the Agilent Measurement Manager software. The U2722A/U2723A can also be programmed using the provided drivers or via SCPI commands.
  • Page 20 Getting Started Floating the U2722A/U2723A output more than ±60 VDC from the WA R N I N G chassis presents an electric shock hazard to the operator. Do not float the outputs more than ±60 VDC when uninsulated sense wires are used to connect the OUTPUT+ to the SENSE+ and the OUTPUT–...
  • Page 21: Product At A Glance

    Getting Started Product at a Glance Product outlook Top view Bumpers U2722A/U2723A User’s Guide...
  • Page 22 Getting Started U2722A USB Modular Source Measure Unit front view Output connector (Channel 1) USB indicator Power indicator U2723A USB Modular Source Measure Unit front view Output connector (Channel 1) USB indicator Power indicator U2722A/U2723A User’s Guide...
  • Page 23 Getting Started U2722A USB Modular Source Measure Unit rear view USB inlet 55-pin backplane connector Fastening hole for USB cable with locking mechanism Power inlet U2723A USB Modular Source Measure Unit rear view USB inlet Rear ventilation fan 55-pin backplane connector...
  • Page 24: Product Dimensions

    Getting Started Product Dimensions Dimensions without bumpers Top view 105.00 mm 175.00 mm Front view 50.00 mm U2722A/U2723A User’s Guide...
  • Page 25: Dimensions With Bumpers

    Getting Started Dimensions with bumpers Top view 120.00 mm 183.00 mm Rear view 66.00 mm U2722A/U2723A User’s Guide...
  • Page 26: Standard Shipped Items

    ✔ Agilent Automation-Ready CD- ROM (contains the Agilent IO Libraries Suite) ✔ Agilent USB Modular Products Quick Start Guide ✔ Agilent USB Modular Products Reference CD-ROM ✔ Agilent Measurement Manager Quick Reference Card ✔ Certificate of Calibration U2722A/U2723A User’s Guide...
  • Page 27: Inspection And Maintenance

    Keep the original packaging in case the U2722A/U2723A has to be returned to Agilent in the future. If you return the U2722A/U2723A for service, attach a tag identifying the owner and model number. Also include a brief description of the problem.
  • Page 28: General Maintenance

    2 Remove your module from the bumper casing. 3 Shake out any dirt that may have accumulated on the module. 4 Wipe your module with a dry cloth and install the bumper back in place. U2722A/U2723A User’s Guide...
  • Page 29: Installation And Configuration

    U2722A/U2723A. You need to install the IVI-COM driver if you are going to use the N O T E ® U2722A/U2723A with Agilent VEE Pro, LabVIEW, or Microsoft Visual ® Studio A. Check your system B.
  • Page 30: Check Your System

    Agilent T&M Toolkit Runtime version 2.1 , Agilent T&M Toolkit Redistributable Package 2.1 patch , Microsoft® .NET Framework version 1.1 and 2.0 [1] Available on the Agilent Automation-Ready CD-ROM. [2] Bundled with Agilent Measurement Manager software application installer. U2722A/U2723A User’s Guide...
  • Page 31: Install The Io Libraries Suite

    The IO Libraries Suite 15.1 or higher is available on the Agilent Automation-Ready CD- ROM that comes with the standard purchase of a U2722A USB Modular Source Measure Unit or U2723A USB Modular Source Measure Unit. • If you do not have the Agilent Automation-Ready CD-ROM, obtain the N O T E IO Libraries Suite 15.0 or higher at http://www.agilent.com/find/iolib.
  • Page 32: Install The Module Driver

    5 Follow the instructions on the screen and click Next to proceed. 6 Click Install to begin the installation. Follow the instructions on the screen to proceed with the installation. 7 Click Finish when the installation has completed. U2722A/U2723A User’s Guide...
  • Page 33: Install The Agilent Measurement Manager

    Step 2. If not, close all other applications on your PC and insert the Product Reference CD-ROM into your CD-ROM drive. 2 Click Measurement Manager on the U2722A/U2723A Installation Menu to begin the installation. 3 If the installation menu does not appear after a few seconds, go to Start >...
  • Page 34: Connect The Module To Your Pc

    2 Insert the DC output plug from the AC/DC power adapter to the power jack on the rear panel of the U2722A/U2723A. 3 Connect the U2722A/U2723A to any USB port on your PC with the bundled USB cable. 4 Your PC will automatically detect the connected unit and the Found New Hardware Wizard window will appear.
  • Page 35 Getting Started 5 Select Install the software automatically (Recommended) and click Next. 6 A warning message will appear on the Hardware Installation window. Click Continue Anyway to proceed with the installation of the U2722A/U2723A. U2722A/U2723A User’s Guide...
  • Page 36 1 Go to Start > Control Panel and double-click System. 2 Select the Hardware tab and click Driver Signing on the Drivers panel. The Driver Signing Options dialog box will appear. 3 Select Ignore to disable the warning message. 7 Click Finish to complete the installation. U2722A/U2723A User’s Guide...
  • Page 37 Getting Started 8 The Assign USB device alias window may appear. Each time the U2722A/U2723A is plugged in, this dialog box will appear. To disable this dialog, select the Never show this dialog option in the Show this dialog panel and click...
  • Page 38 Your U2722A/U2723A is ready for use once the firmware download has completed. 10 The U2722A/U2723A can also be connected remotely to the PC through Agilent E5813A Networked 5-Port USB Hub. 11 To connect through the E5813A, disconnect the U2722A/U2723A from the PC while still powered on.
  • Page 39: Verify Your Module Connection

    1 Go to Start > All Programs > Agilent IO Libraries Suite > Agilent Connection Expert to launch the Connection Expert. 2 The detected U2722A/U2723A will be visible on the Instrument I/O on this PC explorer pane. Right-click on the U2722A/U2723A instrument on the explorer pane.
  • Page 40: Launch Your Agilent Measurement Manager

    • Launching the Measurement Manager without the IO Control running will cause failure of the Measurement Manager to detect or establish any connection with the U2722A/U2723A connected to your PC. • To run the IO Control, go to Start > All Programs > Agilent IO Libraries Suite >...
  • Page 41 3 The Select USB Device dialog box will appear displaying the connected U2722A/U2723A devices. To start the application, select a U2722A/U2723A device and click OK to establish the connection. For more information on how to use the Measurement Manager, refer to N O T E the Agilent Measurement Manager Help File.
  • Page 42: Instrument Configuration

    Getting Started Instrument Configuration Connector configuration The U2722A/U2723A is equipped with output connectors as shown in Figure 1- SENSE OUTPUT GUARD OUTPUT SENSE – – Figure 1-1 Output connectors The SENSE outputs must not be left unconnected. It must be connected N O T E locally or remotely.
  • Page 43: Figure 1-2 55-Pin Backplane Connector Pin Configuration

    Getting Started 55-pin backplane connector pin configuration The 55-pin backplane connector is used when the U2722A/U2723A module is inserted into the U2781A USB modular instrument chassis. For more details, refer to the Agilent U2781A USB Modular Instrument Chassis User's Guide.
  • Page 44: Cable Installation

    Cable casing Push the cables through the cable casing. Cables Connector Then, insert the cables into the cable connector and fasten it. Push the cable casing towards the output connector until it firmly envelops the connector. U2722A/U2723A User’s Guide...
  • Page 45 Getting Started The connector should be enveloped by the cable casing as shown. This figure provides the full view of the connected cables to the instrument’s connector. U2722A/U2723A User’s Guide...
  • Page 46: Chassis Installation

    Getting Started Chassis Installation The L-Mount kit is to be installed to your U2722A/U2723A module. The following instructions describe the simple procedure of installing the L-Mount kit and your module in the chassis. 1 Unpack the L-Mount kit from the packaging.
  • Page 47 Getting Started U2722A/U2723A User’s Guide...
  • Page 48 Memory list commands execution state This chapter describes the source voltage and source current operation mode of the U2722A/U2723A USB Modular Source Measure Units. It also explains the importance of remote sense and guarding when performing low current measurements. There is a section that provides information on extending the U2722A/U2723A output power.
  • Page 49: Operation And Features

    Take note of the following when you power up the U2722A/U2723A. • The U2722A/U2723A can only be operated via the USB interface. • Before you can control the U2722A/U2723A, you need to install the hardware driver and the IO Libraries Suite 14.2 or higher. Both of these are included when you purchase the U2722A/U2723A.
  • Page 50: Sourcing And Measurement

    Operation and Features Sourcing and Measurement The fundamental concepts of the U2722A/U2723A are as shown in Figure 2- 1. When programmed to source voltage mode, the ammeter ) is connected in series with the voltage source (V ) and the...
  • Page 51: Source Voltage Operation

    OUTPUT– terminals of an output channel. 2 Turn on the U2722A/U2723A. The U2722A/U2723A will go into a power-on or reset state; the output is disabled. Ensure that the USB interface has already been connected between the U2722A/U2723A and PC. Run the Agilent Measurement Manager software to control the U2722A/U2723A remotely.
  • Page 52: Figure 2-3 Turning On The U2722A/U2723A

    Figure 2-3 Turning on the U2722A/U2723A Figure 2-4 Turning off the U2722A/U2723A In source voltage mode, the U2722A/U2723A will maintain a constant output voltage based on the set value. The output current will vary according to the load. The input protection current settings represents the limit value.
  • Page 53: Figure 2-5 Source Voltage Positive Operating Boundaries

    Figure 2- 6 shows the operation with different resistive loads, which are 1 kΩ and 100 Ω respectively. In these examples, the U2722A/U2723A is having a source voltage of 15 V and an input protection current of 50 mA. U2722A/U2723A User’s Guide...
  • Page 54: Figure 2-6 Source Voltage Operation

    This forces the U2722A/U2723A to go into source current mode. Since the input protection current setting is set at 50 mA and the U2722A/U2723A cannot operate out of the boundary, the voltage changes to 5 V instead.
  • Page 55: Source Current Operation

    2 Turn on the U2722A/U2723A. The U2722A/U2723A will go into a power-on or reset state; the output is disabled. Ensure that the USB interface has already been connected between the U2722A/U2723A and PC. Load the Agilent Measurement Manager software to control the U2722A/U2723A remotely.
  • Page 56: Figure 2-7 Source Current Positive Operating Boundaries

    Figure 2- 8 shows the operation with different resistive loads, which are 1 kΩ and 100 Ω respectively. In these examples, the U2722A/U2723A is having a source current of 20 mA and an input protection voltage of 15 V. U2722A/U2723A User’s Guide...
  • Page 57: Figure 2-8 Source Current Operation

    This forces the U2722A/U2723A to go into source voltage mode. Since the voltage setting is clamped at 15 V and the U2722A/U2723A cannot operate out of the boundary, the current then changes to 15 mA instead.
  • Page 58: Channel Control Using Scpi Commands

    Set voltage & current range (without any particular priority in sequence). b Set VOLTAGE limit using [:SOURce]:VOLTage:LIMit <voltage>, (@1|2|3), where <voltage> is the value in volts. c Drive CURRENT using [:SOURce]:CURRent[:LEVel][:IMMediate] [:AMPLitude] <current>, (@1|2|3), where <current> is the value in amperes. U2722A/U2723A User’s Guide...
  • Page 59 Sets voltage limit of channel 1 to 10 V. & SOUR:CURR 5mA, (@1) Sets channel 1 to output 5 mA. & OUTP ON, (@1) Turns on output for channel 1. & MEAS:CURR? (@1) Queries the current for channel 1. $ 5.0E-03 U2722A/U2723A User’s Guide...
  • Page 60: Remote Sense And Guard

    The U2722A/U2723A has both local and remote sensing capabilities. When remote sensing is applied, the sense lines can be directly connected to the DUT. When the U2722A/U2723A is in source voltage mode, remote sensing enables the voltage to be sensed at the load and it will result in better regulation.
  • Page 61: Figure 2-10 Remote Sense Connection

    SENSE+ lines and the GUARD line. Therefore, there will not be any leakage current flowing from either the OUTPUT+ and SENSE+ lines. The leakage current from the GUARD does not affect the measurement results because it does not flow into the I meter. U2722A/U2723A User’s Guide...
  • Page 62: Figure 2-11 Guarded Connection

    Never connect the GUARD terminal to any other output, including C A U T I O N circuit common, chassis ground, or the GUARD terminal of any other unit. Doing so may result in damage to the unit. U2722A/U2723A User’s Guide...
  • Page 63: Making Measurements

    Operation and Features Making measurements The U2722A/U2723A has an excellent output voltage and current measurement capability. All the measurements are performed by digitizing the instantaneous output voltage or current for a defined number of samples and sample interval, storing the results in a buffer, and then calculating the measured result.
  • Page 64: Figure 2-12 Commands That Control Measurement Time

    5.115 s. Hence, it is recommended that the time- out settings for communicating with the U2722A/U2723A is set to more than 5.115 s, else time- out error would likely occur.
  • Page 65 Libraries when different values of the sweep points and time interval are set. For more information on how to set the time-out and what are the recommended time-out settings, refer to “Appendix B: Time-out Settings” on page 60. U2722A/U2723A User’s Guide...
  • Page 66: System-Related Operation

    Disconnect all connections from the output terminals. Ensure that the output terminals are not connected to any loads. Turn on the U2722A/U2723A. On the application panel, select Tools > Self-Test. If the self- test fails, an error is recorded in the instrument error queue.
  • Page 67: Error Conditions

    Operation and Features Error conditions A record of up to 20 errors can be stored in the U2722A/U2723A's error queue. Refer to the programming guide for more information on the error messages. Agilent Measurement Manager operation A message box will appear once an error occurs while operating the U2722A/U2723A using the Agilent Measurement Manager.
  • Page 68: Extending The Output Power

    Operation and Features Extending the Output Power The U2722A/U2723A is equipped with three dedicated channels of up to 20 V and 120 mA per channel. Series connections To increase the output voltage, tie two or more of the outputs in series as...
  • Page 69: Parallel Connections

    – Positive (+) terminal of the device-under-test Negative (–) terminal of the device-under-test Figure 2-14 U2722A/U2723A outputs connected in parallel • Ensure that the voltage (when source current) or the current (when N O T E source voltage) is not clamped.
  • Page 70: Memory List

    You may also set the number of times this range of commands is to be executed. The default loop set is 1 and the maximum loop number is 1000. U2722A/U2723A User’s Guide...
  • Page 71: Memory List Commands Storing And Restoring

    Set the global delay value [SOURce:]MEMory:SOURce:DELay LocalDelay Set the local delay value [SOURce:]MEMory:OUTPut Output Enable (ON) or disable (OFF) the instrument output For more information, refer to the Agilent U2722A/U2723A USB Modular Source Measure Units Programmer’s Reference. U2722A/U2723A User’s Guide...
  • Page 72: Memory List Delay Setup

    You can use these programmable delays to perform an even or uneven N O T E sweep. U2722A/U2723A User’s Guide...
  • Page 73: Memory List Commands Execution

    (when trigger signal is received). If the channels are armed and triggered at the same time, they will run in parallel. U2722A/U2723A User’s Guide...
  • Page 74 This command stores the “set current limit to 120 mA” command into the active memory list of (@1) channel 1. & SOUR:MEM:VOLT:SOUR 20, This command stores the “drive voltage 20 V” command into the active memory list of (@1) channel 1. U2722A/U2723A User’s Guide...
  • Page 75 There will be some small time delay between the channels if two or three channels are triggered by the remote command at the same time. The channel execution sequence will start in the order of channel 1, channel 2, and channel 3. U2722A/U2723A User’s Guide...
  • Page 76 This command stores the “set voltage limit to 20 V” command into the active memory list of (@1) channel 1. & SOUR:MEM:CURR:SOUR 0.12, This command stores the “drive current to 120 mA” command into the active memory list of (@1) channel 1. U2722A/U2723A User’s Guide...
  • Page 77: Memory List Commands Execution State

    The WTG bit set indicates that the channel is armed and waiting for trigger. The DTG bit set indicates that the channel is busy and will ignore all incoming commands. U2722A/U2723A User’s Guide...
  • Page 78: Figure 2-15 Channel State And Status Operation Condition Register Bit For External Trigger

    Figure 2-15 Channel state and Status Operation Condition register bit for external trigger WTG = 0 Idle State DTG = 0 WTG = 0 Executing Job State DTG = 1 Figure 2-16 Channel state and Status Operation Condition register bit for remote trigger U2722A/U2723A User’s Guide...
  • Page 79 Operation and Features U2722A/U2723A User’s Guide...
  • Page 80: Characteristics And Specifications

    U2722A/U2723A USB Modular Source Measure Units User’s Guide Characteristics and Specifications Product Characteristics Product Specifications This chapter specifies the characteristics, environmental conditions, and specifications of the U2722A/U2723A. Agilent Technologies...
  • Page 81: Product Characteristics

    • 120.00 × 183.00 × 66.00 mm (with bumpers) • 105.00 × 175.00 × 50.00 mm (without bumpers) WEIGHT • 700 g (with bumpers) • 650 g (without bumpers) WARRANTY One year [1] For remote connections using Agilent E5813A, refer to Chapter U2722A/U2723A User’s Guide...
  • Page 82: Product Specifications

    Output ratings (at 0 ° C to 50 ° C) Voltage –20 V to 20 V Current –120 mA to 120 mA U2722A USB Modular Source Measure Unit performance specifications Range Accuracy Resolution ± 2 V 0.075% + 1.5 mV 0.1 mV...
  • Page 83 23 ° C ± 5° C), ± (% of output + offset) ± 10 mA 0.075% + 7.5 μA 1 μA ± 120 mA 0.1% + 100 μA 20 μA [1] Accuracy measurements are based on NPLC 10. U2722A/U2723A User’s Guide...
  • Page 84 ± 1 μA 170.0 ± 10 μA 18.0 ± 100 μA U2722A USB Modular Source Measure Unit For resistive measurement ± 1 mA ± 10 mA ± 120 mA [1] Drive 50% of 1 V or 10 V output with a resistive load. Rise time is from 10% to 90% of program voltage change at maximum current.
  • Page 85 • = temperature coefficient, and • = temperature change for U2722A USB Modular Source Measure Unit: 22 ° C sto 0 ° C, 28 ° C to 50 ° C temperature change for U2723A USB Modular Source Measure Unit: 18 ° C to 0 ° C, 28 ° C to 50 ° C °...
  • Page 86: Appendixes

    U2722A/U2723A USB Modular Source Measure Units User’s Guide Appendixes Appendix A: List of Self-Test Return Codes Appendix B: Time-out Settings Agilent Technologies...
  • Page 87: Appendix A: List Of Self-Test Return Codes

    Fail Source V/I Pass Fail Source Limit V/I +514 Fail Source Limit V/I Pass Fail Source Limit V/I +528 Pass Fail Source V/I Fail Source Limit V/I +529 Fail Source V/I Fail Source V/I Fail Source Limit V/I U2722A/U2723A User’s Guide...
  • Page 88 Fail Source Limit V/I +544 Pass Fail Source Limit V/I Fail Source Limit V/I +545 Fail Source Fail Source Limit V/I Fail Source Limit V/I +546 Fail Source Limit V/I Fail Source Limit V/I Fail Source Limit V/I U2722A/U2723A User’s Guide...
  • Page 89: Appendix B: Time-Out Settings

    501 to 32767 Assign 110% of t × • Expected time, t = Points Tint N O T E • The Points is set using the SENSe:SWEep:POINts command and the Tint is set using the SENSe:SWEep:TINTerval command. U2722A/U2723A User’s Guide...
  • Page 90 MEAS:CURR?, 40, 44, aperture time. See time, aperture electrical check, MEAS:VOLT?, 39, 44, EMC compliance, measurement capability, error conditions, Measurement Manager InstallShield browser, Wizard, measurement manager. See Agilent Measurement Manager firmware, 20, *CAL, flowchart, *CLS, 39, calibration, self, U2722A/U2723A User’s Guide...
  • Page 91 *RST, 39, latency, real time display, 33, total, recommended calibration interval, relative humidity, operating environment remote interface, U2722A/U2723A Installation Menu. See altitude, remote sensing, 41, Agilent Modular Products Installation humidity, operating range, Menu pollution degree, return code, temperature,...
  • Page 92 Index ® Windows 2000 Professional. See operating system Home Edition. See operating system Vista™. See operating system XP Professional. See operating system U2722A/U2723A User’s Guide...
  • Page 93 Or visit Agilent World Wide Web at: www.agilent.com/find/assist Product specifications and descriptions in this document are subject to change without notice. Always refer to Agilent Web site for the latest revision. © Agilent Technologies, Inc., 2009 - 2011 Fourth Edition, May 2011 U2722-90011 Agilent Technologies...