  • Page 1 Agilent Technologies PCIe High-Speed Digitizer 2 or 8 channels, 8-bit, up to 2 GS/s, DC up to 500 MHz bandwidth, with custom firmware support, suited for embedded OEM applications U5309A Startup Guide...
  • Page 2 Responsible body is the individual or Agilent Technologies, Inc. as governed by shall control. group responsible for the use and United States and international copyright maintenance of equipment, for ensur- laws.
  • Page 3 To prevent electrical shock, disconnect the NOT as safety earth ground connections. unlimited power circuits. They are intended Agilent Technologies instrument from mains If you are using a test fixture, keep the lid to be used with impedance-limited sources. before cleaning. Use a dry cloth or one...
  • Page 4 your instrument. ESD damage is most likely Front and Rear Panel Symbols: to occur as the module is being installed or when cables are connected or disconnected. The CE mark is a registered Protect the circuits from ESD damage by trademark of the European wearing a grounding strap that provides a Community.
  • Page 5: Table Of Contents

    Step 2: Verify U5309A Shipment Contents Step 3: Install the Software System Requirements Hardware Requirements Step 4: Install the Module Agilent U5309A Front Panel Features Step 5: Verify Operation of the U5309A Module Perform a Verification of the U5309A (optional)
  • Page 6: Documentation Map

    Documentation Map Documentation Map U5309A Startup Guide...
  • Page 7: Agilent U5309A Pcie High-Speed Digitizer Introduction

    Agilent U5309A PCIe High-Speed Digitizer Introduction The scope of this Startup Guide is to detail the processes of receiving and installing the Agilent U5309A PCIe High-Speed Digitizer, installing the required software, and verifying basic module operation. If you have any...
  • Page 8 U5309A Startup Guide...
  • Page 9: Step 1: Unpack And Inspect The Module

    3. Write the following information on a tag and attach it to the malfunctioning equipment: Name and address of owner. A P.O. box is not acceptable as a return address. Product model number (for example, U5309A). Agilent U5309A Startup Guide...
  • Page 10: Step 2: Verify U5309A Shipment Contents

    5. On the shipping label, write ATTENTION REPAIR DEPARTMENT and the RMA number. If any correspondence is required, refer to the product by serial number and model number. Step 2: Verify U5309A Shipment Contents The following items are also included with your U5309A PCIe High-Speed Digitizer order: Part Number Quantity Description U5309A PCIe High-Speed Digitizer.
  • Page 11: Step 3: Install The Software

    2. Follow the installer prompts. Choose a "Complete" installation to install all software and documentation, or a "Custom" installation to select from a listing of components and other features. 3. After installation is complete, please shut-down the PC. Agilent U5309A Startup Guide...
  • Page 12: Step 4: Install The Module

    Follow ESD precautions when handling and installing the U5309A. 2. The U5309A features a x8 PCIe bus interface, and should be installed in either a x8 or x16 slot. 3. When installing the U5309A ensure that it has optimum cooling, do not install it in a position where the integrated cooling fans may be obstructed.
  • Page 13 Step 4: Install the Module Note that the U5309A is optionally supplied with a card retainer (included if ordered as U5300A-001, or available separately by ordering U1092-CRM) which is able to pick up on slots at the end the full-length PCIe slot and provide additional support for the module.
  • Page 14 4. Slide the fan unit back towards the module until it is fully seated into the locating slots. 5. Refit the 4 screws, push the fan unit upwards away from the circuit board and tighten the four screws (0.5 Nm torque). U5309A Startup Guide...
  • Page 15: Agilent U5309A Front Panel Features

    (U1092-WCK) before connecting the SMA end, this minimizes strain on the connector. A 1 m SSMC to SMA cable is available as an accessory (U1092-CB3). For the 2 channels version (U5309A-CH2 option) For the 8 channels version (U5309A-CH8 option) Agilent U5309A Startup Guide...
  • Page 16 Note: If warning or error status is observed, please try the following steps: Power-cycle the chassis (If using a PCIe interface to external PC, observe the power sequence require- ments) If the error persists please contact Agilent technical support U5309A Startup Guide...
  • Page 17: Step 5: Verify Operation Of The U5309A Module

    Step 5: Verify Operation of the U5309A Module Step 5: Verify Operation of the U5309A Module The intention of this step is to verify correct operation of the newly installed module. Run Agilent Connection Expert by right-clicking the task bar icon , and select Agilent Connection Expert.
  • Page 18: Perform A Verification Of The U5309A (Optional)

    Perform a Verification of the U5309A (optional) Requirements for Verification The correct operation of the U5309A may be verified by the use of a simple application which carries out several performance checks on a signal acquired from an external Function Generator.
  • Page 19 U5309A Startup Guide...
  • Page 20 As with a tangram, the possibilities may seem infinite as you begin to create For more information on Agilent Technologies' products, a new test system. With a set of clearly defined elements—...

Table of Contents