Agilent Technologies U2300A Series User Manual page 97

Usb multifunction data acquisition devices
Hide thumbs Also See for U2300A Series:
Table of Contents

Advertisement

N O T E
U2300A Series USB DAQ User's Guide
Example 3:
// Analog Trigger with first scan channel as trigger channel (SONE mode)
-> OUTP:TRIG:SOUR EXTA
-> ROUT:SCAN (@133)
-> OUTP:TRIG:ATRG:SOUR SONE // Above High threshold Trigger
-> OUTP:TRIG:ATRG:COND AHIG
-> OUTP:TRIG:ATRG:HTHR 4
-> OUTP:TRIG:ATRG:LTHR 1
-> OUTP:TRIG:TYPE POST
-> ROUT:ENAB ON,(@201)
-> RUN
-> OUTP ON
For SONE mode, execute the RUN/DIG command first before turning on
the output. Channel 133 will only respond to trigger signal during
acquisition.
Features and Functions
// Use Channel 133 as trigger
channel
condition
// 4 V High Threshold
// 1 V Low Threshold
// Important!
3
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

U2331aU2351aU2352aU2353aU2354aU2355a ... Show all

Table of Contents