3
Features and Functions
76
Example 2:
// Digital trigger with Middle trigger type
-> WAV:POIN 1000
-> ACQ:SRAT 1000
-> TRIG:SOUR EXTD
-> TRIG:DTRG:POL POS
-> TRIG:TYPE MID
-> RUN
Example 3:
// Analog trigger with Pre trigger type
-> ACQ:POIN 1000
-> ACQ:SRAT 1000
-> ROUT:SCAN (@101)
-> ROUT:CHAN:POL BIP,(@101)
-> TRIG:SOUR EXTA
-> TRIG:ATRG:COND AHIG
-> TRIG:ATRG:HTHR 3
-> TRIG:ATRG:LTHR –3
-> TRIG:TYPE PRE
-> DIG
// Trigger will happen when signal go above 3 V
// For "RUN" mode
// Digital Trigger
// For "DIG" mode
// Analog trigger
// Above high Threshold condition
// 3 V high Threshold
// –3 V low Threshold
// Pre trigger