7. Shake the filter over a container until most of the water is removed.
8. Place the filter on its edge on a flat, stable surface and allow it to dry thoroughly.
9. To confirm that the filter is dry, place it over a dry paper towel and shake it. If the paper towel
remains dry, the filter can be installed in the projector.
10. Record the date the filter was cleaned.
11. Replace the filter following the instructions for the specific filter.
The lens seals the projection head, preventing contaminants from entering the main electronics area. Do not
operate the projector without a lens installed. Install a lens plug when you install or transport the projector.
1. On the touch panel Main screen, tap and hold the power button to turn off the and projector.
2. Allow the to cool for a minimum of 15 minutes.
3. Disconnect the projector from AC power or turn the circuit breaker off.
4. Install the lens cap and turn the lens clamp to the open position.
5. If necessary, remove the two cap screws securing the lens to the lens mount using a hex key.
6. Pull the lens out of the lens mount and then install a small lens cap on the rear of the lens.
7. Remove the small rear cap from the new lens.
Keep the front cap on.
8. Align the tabs on the lens plate with the lens mount.
9. Insert the lens until it connects with the magnets on the mount.
When the lens contacts the magnetic plates it is seated correctly.
10. Secure the lens clamp by rotating it clockwise.
11. Tighten the lens mount cap screws for added stability.
12. Remove the lens cap from the front of the lens.
CP2306-RGBe, CP2308-RGBe, CP2310-RGBe User Manual