Advertisement

4. Tap Save.
Delete a storage device when it is no longer required.
1. In the left navigation menu, tap Service Setup > Storage Device Setup.
2. In the left pane, tap a storage device.
3. Tap Delete.
4. To confirm the deletion, tap Delete.
Add a remote ingest source to uploaded content from a remote storage device.
1. In the left navigation menu, tap Service Setup > Remote Ingest Setup.
2. Tap + New Ingest Source.
3. In the Name field, type a name for the ingest source.
4. In the IP Address field, type an IP address for the ingest source.
5. Tap Add.
6. In the right pane, enter a user name and a password if required for the ingest source.
7. Tap the Type list and select the device type.
8. To test the connection to the ingest source, tap Test Connection.
9. To save the configuration, tap Save.
Edit the settings of remote ingest sources when device or communication settings change.
1. In the left navigation menu, tap Service Setup > Remote Ingest Setup.
2. In the left pane, tap a remote ingest source.
3. Edit the settings displayed in the right pane.
4. Tap Save.
Delete a remote ingest source when it is no longer required.
1. In the left navigation menu, tap Service Setup > Remote Ingest Setup.
2. In the left pane, tap a remote ingest source.
3. Tap Delete.
CP2306-RGBe, CP2308-RGBe, CP2310-RGBe User Manual
020-001835-02 Rev. 1 (05-2021)
Copyright
2021 Christie Digital Systems USA, Inc. All rights reserved.
©
Managing storage devices
65