and select to use back pressure as a means of ßow control. The default
settings are:
The command by itself displays the following:
ELS10-27>switch
The present switch mode is: 802.1d
The switch mode upon the next reboot will be: 802.1d
The forwarding mode in use is: Store and Forward
Backpressure is off
Port
The Port command,
port
[PORT-RANGE [speed {auto | 10[Mbps] | 100[Mbps]}]
[duplex [{auto | full[-duplex] | half[-duplex]}]]
[storm THRESHOLD TIME-INTERVAL]
[vlan {name |VLAN-ID}]
[802.3x [ßow control] {on | off}]
[GVRP {On | off}]
[access
allows you to conÞgure the port(s) on the unit in regards to speed, duplex
mode, broadcast storm protection values and default VLAN ID used on
each port. You are not allowed to name the VLAN here. Refer to the vlan
command to name a vlan. By setting the default VLAN ID for a port, the
port WILL NOT automatically become a member of that VLAN. The
VLAN must be created Þrst using the VLAN command and this port
made a member. Likewise, if the default VLAN ID is changed, the port is
not removed from the old VLAN, you must use the VLAN command and
remove the port from the VLAN. In addition, you are able to specify if
GVRP is enabled for these ports. If enabled, GVRP messages are received
on these ports and GVRP messages are propagated to these ports.
1-26
802.1d mode
store-and-forward
Backpressure off
{add | del[ete]}]]