1.5.3.
1.5.4.
1.6.
1.6.1.
12
Two limit switches on saw arm control if cowers are open or not.
Saw band stretching and rupture inspection
This device checks the saw band stretching and causes immediate machine shut –
down in the event the band ruptures.
The device contains limit switch. Check the stretching carefully and periodically –
eventually adjust.
Band saw cover
It covers the visible area of the saw band from left guiding cube to the frame.
Never switch on the saw band driver if this cover is not mounted!
Safety notes for the cooling
Attention!
When handling cooling agents always wear hazardous
fluid-proof gloves!
Wear protective goggles!
Cooling liquid can get in contact with your eyes and may
cause permanent severe injuries
Instructions for first help
1.
Pull off and safely remove polluted, soaked clothing.
2.
For breathing, go out in the fresh air or look for first aid treatment.
3.
Wash with water or use crèmes for contact with the skin.
4.
Flush with water for eyes and look for first aid treatment.
Manual version:
1.10 / Jan. 2011
Manual rev.:
1