Vertical Flue Extension Kit (Part #946-756); Ceiling Firestop / Firestop Spacer (Part #946-757) - Regency Fireplace Products Panorama P33CE Series Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

installation
|
34

VERTICAL FLUE EXTENSION KIT (PART #946-756)

VERTICAL FLUE EXTENSION KIT (PART # 946-756)
20 foot (6.1 m) Flex pipe Extension
(Used in conjunction with the 946-755 Vertical Flex kit and 948-367/P flex
CEILING FIRESTOP/FIRESTOP SPACER
to flex adaptor).
( PART # 946-757)
1. Stretch out both inner 4" (102 mm) and outer 6 7/8" (175 mm) pipe up to
a maximum of 20 feet.
Used in conjunction with the 946-755 Vertical flex kit and 946-756 kit Vertical
flex extension kit/Horizontal power vent kit.
Note :The inner and outer pipes may be cut if only a short length is required.
A ceiling firestop/firestop spacer must be installed when passing through
2. Install spring spacers around 4" (102 mm) inner pipe as shown.
each floor or ceiling level. To install the ceiling firestop/firestop spacer in
Slide outer flex pipe over and all the way down the 4" pipe.
a flat ceiling or floor joist cut a 10- ¼ inch square hole. Frame the hole as
show in Diagram 1 and install the ceiling firestop. Slide the top attic insula-
3. Apply a bead of Mill Pac around the perimeter of the 4" (102 mm)
tion spacer onto the top of the attic insulation shield/firestop - See Diagram
inner collar of the flex adapter and slip the 4" (102 mm) inner flex pipe
1a. Secure with 4 screws/nails. If more than one is required, these can be
from the Vertical termination kit over the flex adapter ensuring that the
purchased separately.
inner flex pipe overlaps the collar by at least 1-3/8" (35 mm). Fasten with
3 screws.
Note: The ceiling firestop/firestop spacer may be cut down to size if this shield
is too high for the application.
4. Apply a bead of Mill Pac around the perimeter of the 6-7/8" (175 mm)
outer collar of the flue adapter and slip it over the 6-7/8" (175 mm) outer
flex pipe from the vertical termination kit ensuring that the outer flex pipe
overlaps the collar by at least 1-3/8" (35 mm). Fasten with the 3 screws.
5. Repeat steps to secure the other end of the flex adapter using the flex kit.
6. See Vertical Vent installation instructions for installation of the complete
vent system.
Note: If an offset is necessary in the attic or floor joists it is important to
sup-port the vent pipe every 3 feet (0.91 m) to avoid excessive stress and
sagging of the vent pipe. Wall straps are provided (3 in total) for this
919-698
purpose.
All round/plumbers strapping may also be used if further supports are
required.
CEILING FIRESTOP/FIRESTOP SPACER
( PART # 946-757)

CEILING FIRESTOP / FIRESTOP SPACER (PART #946-757)

Used in conjunction with the 946-755 Vertical flex kit and 946-756 kit Vertical
flex extension kit/Horizontal power vent kit.
A ceiling firestop/firestop spacer must be installed when passing through
each floor or ceiling level. To install the ceiling firestop/firestop spacer in
a flat ceiling or floor joist cut a 10- ¼ inch square hole. Frame the hole as
show in Diagram 1 and install the ceiling firestop. Slide the top attic insula-
tion spacer onto the top of the attic insulation shield/firestop - See Diagram
1a. Secure with 4 screws/nails. If more than one is required, these can be
purchased separately.
Note: The ceiling firestop/firestop spacer may be cut down to size if this shield
is too high for the application.
34 |
919-698
P33CE-10 Direct Vent Gas Fireplace
919-696
4" (102 mm) inner
pipe 20ft. (6.1 m)
-1/4
60
Ceiling firestop
Diagram 1
6-7/8" (175 mm)
Diagram 1a
outer flex pipe
20 ft (6.1 m)
1
-1/4
60
Ceiling firestop
Diagram 1
Diagram 1a
1
1
10 spring spacers
Termination Cap
Storm Collar
Flashing
Firestop spacer to prevent
flex adaptor
debris from falling into the ceiling
firestop
Roof support
3 wall straps
Ceiling firestop
Enclosure
Ceiling firestop
06.12.18
Termination Cap
Storm Collar
Flashing
Firestop spacer to prevent
debris from falling into the ceiling
Roof support
firestop
Ceiling firestop
Enclosure
Ceiling firestop
06.12.18
08.10.16