Clearances With Vignette Faceplate; Mantel Leg Clearances With Flush Glass - Regency Fireplace Products Panorama P33-10 Owners & Installation Manual

Table of Contents

Advertisement

installation
|
18

CLEARANCES WITH VIGNETTE FACEPLATE

The clearances listed below are Minimum
distances unless otherwise stated:
A major cause of chimney related fires is
failure to maintain required clearances
(air space) to combustible materials.
It is of the greatest importance that this
fireplace and vent system be installed
only in accordance with these instruc-
tions.
Clearance to Combustibles from:
Back
0"
Side
0"
Floor
0"
NOTE: The minimum floor clearance must be
maintained
from the top surface of the carpeting, tile, etc.
Minimum Clearance from Top of Unit to:
Mantel*
min. 10" (254mm)
Ceiling
30"
from top of unit.

MANTEL LEG CLEARANCES WITH FLUSH GLASS

Combustible mantel leg clearances from side of unit as per diagram:
Maximum
1-1/2" projection at 2" mini-
mum clearance.
18 |
Regency
P33-10 Zero Clearance Direct Vent Gas Fireplace
®
Side Wall Clearance
Minimum Vent Clearances:
2-1/2" (64mm) Horizontal Top
1-1/2" (38mm) Horizontal Side
1-1/2" (38mm) Horizontal Bottom
1-1/4" (32mm) Vertical Vent Clearance
(Rigid Vent)
1-1/2" (38mm) Vertical Vent Clearance
(Flex Vent)
Alcove Clearances:
Max. Depth
(0mm)
Min. Width
(0mm)
Min. Height
(0mm)
* see mantel clearance instructions.
(762mm)
7-1/2" (191mm)
36"
(914mm)
48"
(1219mm)
59"
(1499mm)
Clearances for Vignette Faceplate
Warning
Fire hazard is an extreme risk if these
clearances are not adhered to.