Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Control Options
©
Danfoss | May 2017
Nominal supply voltage
Supply current
PWM frequency
Electrical protection class
Bi-directional diode cut off voltage
Brake gauge port with MDC
C
Caution
It is not recommended to use brake port for any external flow consumption to avoid malfunction of CCO
function.
12 V
850 mA
Maximum
580 mA
Minimum
50-200 Hz
Range
100 Hz
Preferred
IP67 / IP69K with mating connector
28 V
11063344 | BC00000059en-US1001 | 37
24 V
430 mA
300 mA
50-200 Hz
100 Hz
53 V
Need help?