Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Control Options
©
Danfoss | May 2017
Pump displacement vs. input signal
100 %
NFPE control
Signal Current
mA(DC)
c
b
a
"0"
Control Signal Requirements, NFPE 045/053 Single
Control current
*
Voltage
a
12 V
310 mA
24 V
309 mA
*
Factory test current, for vehicle movement or application actuation expect higher or lower value.
1
2
P003 480
Connector ordering data
Description
Mating connector
Wedge lock
Socket contact (16 and 18 AWG)
Danfoss mating connector kit
Solenoid data
Description
Maximum current
Nominal coil resistance
@ 20 °C [68 °F]
@ 80 °C [176 °F]
Inductance
PWM signal frequency
Range
Recommended
a
b
c
100 %
P003 187E
b
c
1050 mA
1540 mA
551 mA
770 mA
Quantity
1
1
2
1
12 V
1800 mA
3.66 Ω
4.52 Ω
33 mH
70 – 200 Hz
*
200 Hz
Pin connections
any order
Ordering data
DEUTSCH DT06-2S
DEUTSCH W2S
DEUTSCH 0462-201-16141
K29657
24 V
920 mA
14.20 Ω
17.52 Ω
140 mH