Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Control Options
©
Danfoss | May 2017
Typical response times at the following conditions:
∆p
Viscosity and temperature
Charge pressure
Speed
Response time, EDC 045/053
Stroking direction
0.8 mm [0.03 in] orifice
Neutral to full flow
1.7 s
Full flow to neutral
1.1 s
250 bar [3626 psi]
30 mm²/s [141 SUS] and 50 °C [122 °F]
20 bar [290 psi]
-1
1800 min
(rpm)
1.3 mm [0.05 in] orifice
0.9 s
0.6 s
No orifice
0.5 s
0.3 s
11063344 | BC00000059en-US1001 | 19