PILOT
LAMP(S)
BEEPER
ON
4 short
beeps
every
5
minutes
Short
beeps
repeating
rapidly
2 short
beeps
2 short
beeps,
repeating
D.E.S.S.
slowly
Short
beeps
repeating
rapidly
MESSAGE
DISPLAY
REV LIMIT
OVER REV
SHUTDOWN
COMMUNICATION
CHECK KEY
BAD KEY
(blinking)
THROTTLE OPEN
DROWN MODE
______________
DESCRIPTION
Engine RPM limited for protection when
certain faults occur.
On E-TEC engines, indicates that maximum
engine RPM is reached. Check clutch
calibration.
Shutdown procedure in force due to engine
overheating or fuel pump problem, remove
tether cord cap from engine cut-off switch
and contact an authorized Lynx dealer.
Communication problem between ECM
and gauge. Stop engine, remove tether
cord cap. Wait a few minutes, then start
engine. If problem persists, contact an
authorized Lynx dealer.
Good key, vehicle ready to operate.
Unable to read key (bad connection). Make
sure the key is clean and correctly snapped
on post.
Invalid key or key not programmed. Use
the proper key for the vehicle or have the
programmed.
Fuel level sensor problem.
Throttle lever applied while attempting an
engine start (engine cranks but won't run).
Release throttle while starting.
Throttle lever wide open while attempting
an engine start (engine cranks but won't
run). Release throttle while starting.