Maintenance and servicing
5.2.4

Changing the battery

Warning
• Only use batteries approved by Hako at the intended position!
• The battery should only be changed by trained operating staff!
• Wear safety shoes and protective gloves when changing the
battery.
• When raising and lowering the battery trough with a crane, there
is a risk of injury from falling and uncontrolled swinging parts.
• The operator must be instructed by the owner in the operation
of the crane and informed of the risks associated with its
operation.
• Only use the attachment points provided.
• When changing the battery trough, use a suitable battery
changing cross-beam (according to VDI 3616) and sufficiently
load-bearing crane gear.
• Do not hook in the chains at too shallow an angle, otherwise
the tensile forces in the chains can increase to several times
the weight of the battery and the chains may break.
• Do not lower or place lifting gear and chains (according to
VDI 3616) on the battery cells.
• Never use damaged crane gear.
• Lifting hooks should not cause damage to battery cells,
connectors or connecting cables.
• Keep a sufficient distance from the battery trough.
• Attach the crane hook ensuring it is centred over the battery
trough.
• Carefully lift the battery trough and ensure that the battery
trough does not tip over. Change the attachment point if
necessary.
• When using other batteries which have been approved by Hako,
the BMS must be reset to protect the battery against total
discharge. The settings of the BMS must only be carried out by a
Hako service workshop!