Introduction; Instruction Manual Structure; Models Covered By This Manual; Product Description - ABB 2600T Series Instruction Manual

266 with foundation fieldbus communication
Table of Contents

Advertisement

4
2 6 0 0 T S E R I E S | P R E S S U R E T R A N S M I T T E R S | O I/ 2 6 6/ F F - E N R E V. E
1

Introduction

Instruction manual structure

The present manual provides information on installing,
operating, troubleshooting the 266 pressure transmitter. Every
section of the present manual is specifically dedicated to the
specific phase of the transmitter lifecycle starting from the
receipt of the transmitter and its identification, passing to the
installation, to the electrical connections, to the configuration
and to the troubleshooting and maintenance operations.

Models covered by this manual

The present manual can be used for all the 266 models with
exception done for the 266C (multivariable version).

Product description

The pressure transmitters model 266 is a modular range of
fieldmounted, microprocessor based electronic transmitters,
multiple sensor technologies. Accurate and reliable
measurement of differential pressure, gauge and absolute
pressure, flow and liquid level is provided, in the even most
difficult and hazardous industrial environments. Model 266 can
be configured to provide specific industrial output signals
according to FOUNDATION Fieldbus communication.
2

Safety

General safety information

The "Safety" section provides an overview of the safety
aspects to be observed for operation of the device.
The device has been constructed in accordance with the state
of the art and is operationally safe. It has been tested and left
the factory in perfect working conditions. The information in
the manual, as well as the applicable documentation and
certificates, must be observed and followed in order to
maintain this condition throughout the period of operation.
Full compliance with the general safety requirements must be
observed during operation of the device. In addition to the
general information, the individual sections in the manual
contain descriptions of processes or procedural instructions
with specific safety information.
Only by observing all of the safety information can you reduce
to the minimum the risk of hazards for personnel and/or
environment. These instructions are intended as an overview
and do not contain detailed information on all available models
or every conceivable event that may occur during setup,
operation, and maintenance work.
For additional information, or in the event of specific problems
not covered in detail by these operating instructions, please
contact the manufacturer. In addition, ABB declares that the
contents of this manual are not part of any prior or existing
agreements, commitments, or legal relationships; nor are they
intended to amend these.
All obligations of ABB arise from the conditions of the relevant
sales agreement, which also contains the solely binding
warranty regulations in full. These contractual warranty
provisions are neither extended nor limited by the information
provided in this manual.
WARNING
Only qualified and authorized specialist personnel should
be charged with installation, electrical connection,
commissioning, and maintenance of the transmitter.
Qualified personnel are persons who have experience in
installation, electrical wiring connection, commissioning,
and operation of the transmitter or similar devices, and
hold the necessary qualifications such as:
• Training or instruction, i.e., authorization to operate and
maintain devices or systems according to safety
engineering standards for electrical circuits, high
pressures, and aggressive media
• Training or instruction in accordance with safety
engineering standards regarding maintenance and use of
adequate safety systems.
For safety reasons, ABB draws your attention to the fact
that only sufficiently insulated tools conforming to DIN EN
60900 may be used.
Since the transmitter may form part of a safety chain, we
recommend replacing the device immediately if any defects
are detected. In case of use in Hazardous Area non sparking
tools only must be employed.
In addition, you must observe the relevant safety regulations
regarding the installation and operation of electrical systems,
and the relevant standards, regulations and guidelines about
explosion protection.
WARNING
The device can be operated at high levels of pressure and
with aggressive media. As a result, serious injury or
significant property damage may occur if this device is
operated incorrectly.

Improper use

It is prohibited to use the device for the following purposes:
• As a climbing aid, e.g., for mounting purposes
• As a support for external loads, e.g., as a support for pipes.
• Adding material, e.g., by painting over the name plate or
welding/soldering on parts
• Removing material, e.g., by drilling the housing.
Repairs, alterations, and enhancements, or the installation of
replacement parts, are only permissible as far as these are
described in the manual. Approval by ABB must be requested
for any activities beyond this scope. Repairs performed by
ABB-authorized centers are excluded from this.