2 6 0 0 T S E R I E S | P R E S S U R E T R A N S M I T T E R S | O I/ 2 6 6/ F F - E N R E V. E
128 (5.04)
72 (2.83)
105 (4.13)
Figure 23: Model 266G or 266A P-Style transmitter with DIN housing installed on a 2"pipe with optional bracket
(B2 Stainless Steel 316L)
DIN Housing bracket details
B2 bracket
U-bolt fixing bolt
and washer
Figure 24: Pipe and wall mounting bracket kit (B2) for P style transmitter with DIN housing
83 (3.27)
18 (0.71)
U-bolt
Transmitter fixing bolts
29 (1.14)
120 (4.72)
18 (0.71)
1/2 - 14 NPT
22 (0.87) width across
flats of exagon
30 (1.19)
66 (2.60)
117 (4.60)