ABB 2600T Series Instruction Manual page 60

266 with foundation fieldbus communication
Table of Contents

Advertisement

60
2 6 0 0 T S E R I E S | P R E S S U R E T R A N S M I T T E R S | O I/ 2 6 6/ F F - E N R E V. E
. . .Block Mapping
Idx
Parameter
15
PRIMARY_VALUE
16
PRIMARY_VALUE_RANGE
17
CAL_POINT_HI
18
CAL_POINT_LO
19
CAL_MIN_SPAN
20
CAL_VALUE
21
CAL_UNIT
22
XD_OPTION
23
SENSOR_TYPE
24
SENSOR_RANGE
25
SENSOR_SERIAL_NUMBER
26
SENSOR_CAL_METHOD
27
SENSOR_CAL_LOC
28
SENSOR_CAL_DATE
29
SENSOR_CAL_WHO
SENSOR_DIAPHRAGM_
30
MATERIAL
31
SENSOR_FILL_FLUID
32
SECONDARY_VALUE
33
SECONDARY_VALUE_RANGE
34
TERTIARY_VALUE
35
TERTIARY_VALUE_RANGE
36
QUATERNARY_VALUE
37
QUATERNARY_VALUE_RANGE
38
QUATERNARY_LIN_TYPE
39
QUATERNARY_VALUE_CUT_OFF 0% to 20% [default = 6%]
QUATERNARY_VALUE_LINEAR_
40
POINT
41
DESIDERED_PV
42
RESET_BIAS
43
BIAS_VALUE
44
STATIC_P_CAL_POINT_HI
Description / Range / Selections / Notes
Pressure Process (PdP) in output from PRTB and input to the AI with Channel = 1
The High and Low range limit values, the engineering units code and the number of digits to the right of the decimal
point Used as input scaling for the production of the Scaled PV
PdP Sensor Calibration point High value expressed in CAL_UNIT
PdP Sensor Calibration point Low value expressed in CAL_UNIT
PdP Sensor Calibration minimum Span value expressed in CAL_UNIT. When calibration is done, the two calibrated
points (high and low) must not be too close together.
PdP Process Value after the Calibration. Reference value to be adjusted with the calibration operations
Calibration Unit.
Options which the user may select to alter transducer
behavior.
Type of Sensor
The High and Low PdP physical sensor limits with the engineering units code (Press Only)
Serial Number of the sensor
The method of last sensor calibration. ISO defines several standard methods of calibration. This parameter is
intended to record that method, or if some other method was used.
The location of last sensor calibration.
The date of the last sensor calibration.
The name of the person responsible for the last sensor calibration.
Defines the construction material of the isolating diaphragms.
Defines the type of fill fluid used in the sensor
Sensor Temperature in output from PRTB and input to the AI with Channel = 2
The High and Low Sensor Temp Limits with the engineering units code (Temp Only)
Static Pressure in output from PRTB and input to the AI with Channel = 3
The High and Low Static Pressure Sensor Limits with the engineering units code
(Press Only)
Scaled_PV in in output from PRTB and input to the AI with Channel = 4
The High and Low Scaled_PV Limits with the engineering unit code.
Used as Output Scaling to produce the Scaled_PV
0
Linear (default)
1
Square root
2
SQRT 3° pow
3
SQRT 5° pow
4
cylindrical lying container
5
spherical container
6
Bidirectional Flow
0% or 5% to 20% [default = 5%]
Expressed in PRIMARY_VALUE_UNIT
Reset BIAS_VALUE to 0.0 so that  PRIMARY_VALUE = CAL_VALUE
Expressed in PRIMARY_VALUE_UNIT
Static Pressure Calibration point High expressed in STATIC_P_CAL_UNIT
Only Pressure Units are allowed
Bit 0: Connected Channel Status BAD in MAN (LSB)*
Bit 1: Connected Channel Status UNC in MAN
TN-016 – 121 = Pressure sensor unknown
Only the Unit is changeable.
The limits/ranges are
automatically converted.
Only the Unit is changeable.
The limits/ranges are
automatically converted.
Fixed set to 0 / 100 % with
2 decimals
Transfer Function for
Scaled_PV
Valid Only for QUATERNARY_LIN_TYPE = Square Root or
Bidirectional Flow
Force the Measured Pressure to a selected Value setting
an offset between Measured and Process values  PV =
MV +/- BIAS  PRIMARY_VALUE = CAL_VALUE +/- BIAS_
VALUE
Read the offset between the Measured and Process values
 BIAS_VALUE = CAL_VALUE – PRIMARY_VALUE