ABB 2600T Series Instruction Manual page 116

266 with foundation fieldbus communication
Table of Contents

Advertisement

116
2 6 0 0 T S E R I E S | P R E S S U R E T R A N S M I T T E R S | O I/ 2 6 6/ F F - E N R E V. E
. . .Block Mapping
Idx Parameter
Description / Range / Selections / Note
Defines the type of counting (up or down) and the type of resetting (demand or periodic)
0
1
2
3
28
INTEG_TYPE
4
5
6
7
A bit string to configure the type of input (rate or accum.) used in each input, the flow direction to be considered in the totalization,
the status to be considered in TOTAL and if the totalization residue shall be used in the next batch
(only when INTEG_TYPE = UP_AUTO or DN_AUTO).
Bit 0
Bit 1
Bit 2
29
INTEG_OPTS
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
30
CLOCK_ERR
0 or > 0
31
PRE_TRIP
0 or > 0
The number of resets is counted in the register N_RESET. This counter can not be written or reset. It provides verification that the
32
N_RESET
TOTAL has not been reset since N_RESET was last checked. The counter should roll over from 999999 to 0.
33
PCT_INCL
This value is the % of the absolute net increment with good status respect of the absolute net increment regardless of the status.
If PCT_INCL ≥ GOOD_LIM and the mode is AUTO the status of the OUT is GOOD_NC otherwise check the other limit. Expressed in %
34
GOOD_LIM
If PCT_INCL ≥ UNCERT_LIM and the mode is AUTO the status of the OUT is UNCERTAIN otherwise is BAD. Expressed in %
35
UNCERT_LIM
0
36
OP_CMD_INT
1
37
OUTAGE_LIM
0 or > 0
0
38
RESET_CONFIRM
1
39
UPDATE_EVT
This alert is generated by any change to the static data
The block alarm is used for all configuration, hardware, connection failure or system problems in the block. The cause of the alert is
entered in the subcode field. The first alert to become active will set the Active Status in the status parameter. When the
40
BLOCK_ALM
Unreported status is cleared by the alert reporting task, another block alert may be reported without clearing the Active Status, if
the subcode has changed
Not Initialized
UP AUTO
UP DEM
DN AUTO
DN DEM
PERIODIC
DEMAND
PER & DEM
Input 1 Accumulate
Input 2 Accumulate
Flow Forward
Flow Reverse
Use Uncertain
Use Bad
Carry
Add zero if Bad
Confirm Reset
Generate Reset Event
Establishes the period for periodic reset, in seconds
Value used for the OUT_PTRIP setting. It adjusts the amount of mass, volume or energy that should
set OUT_PTRIP when the integration reaches (TOTAL_SP - PRE_TRIP) when counting UP or PRE_
TRIP when counting DOWN. Expressed in OUT_RANGE Unit
OFF
Operator reset command. Resets the totalizer
ON
The max, tolerated duration for power failure. This value is used by the host expressed in seconds
If the Confirm Reset in the INTEG_OPTS is set, any further reset will be prevented until a logic 1 is
OFF
not received in input to the RESET_CONFIRM. If not connected it acts like a momentary dynamic
parameter. This ensures that a host has recorded the snapshot values before the next reset can
CONFIRM
occur.