ABB 2600T Series Instruction Manual page 27

266 with foundation fieldbus communication
Table of Contents

Advertisement

2 6 0 0 T S E R I E S | P R E S S U R E T R A N S M I T T E R S | O I/ 2 6 6/ F F - E N R E V. E
Pressure or absolute pressure measurement of a tank
• Place the taps in the upper part of the tank.
• Mount the transmitter above the elevation of the process tap
(both pressure and differential pressure transmitter can be
used).
• Connect the transmitter to the tank.
Figure 33: Gauge or absolute pressure measurement on a tank
Pressure or absolute pressure measurement of a liquid in a pipe
• Place the tap at the side of the line.
• Mount the transmitter (both pressure and differential pressure
transmitters) beside or below the tap for clean fluids, above the
tap for dirty fluids.
• Connect the + (H) side of the transmitter to the pipe.
Figure 34: Gauge or absolute pressure measurement of a liquid in a pipe
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

266

Table of Contents