○ When W delay is negative, B delay is referenced to MCU's clock rather
than added delay. For example, in time lapse sessions, for W:-0.001
sec and B:5 sec, the result will be a shot at every 5 seconds. If
movements are executed, the value of B needs to be large enough to
cover the time taken by the move.
○ Also, when W delay is negative, a log file – /intervals.txt – will be
produced, with all the intervals, in ms, between the triggers of the
shutter done by MECHA.
● B (Before) — The pause before each triggering sequence. If the value is
negative, up to 2 seconds will be used for Mirror Lock Up.
● M (Modifier of Exposure) — Modifier of the duration of shutter button
signal, a list of multipliers, like 1,0.5,2 for normal, half and double
exposure time, respectively, in case of 3 TRG, or it can be entered as -
0.7EV (for under, normal, over), or 0.7EV (for normal, under, over), in
which case it will automatically extend to the number of TRG. If the
modifier starts with B, like B-2EV, or B1, or 1,0.5,2, the "Bulb" mode will
be assumed.
● E (Exposure) — Duration of shutter button signal, for example, 3 or 0.5*3
for progressive half Exposure, or 2*3 for progressive double Exposure in
a set. These can be entered as custom values. The values can be entered
as 1/100.
○ E: SHT C., E: SHT C1 — When these options are selected, shutter
confirmation will be used if Enable Fast Shutter Confirmation checkbox
is checked on Configuration page. Both options work as a variable
pause. In the case of the E: SHT C1 option, MECHA sends only One
Signal to the camera and waits for TRG confirmations. This is useful
when you have your camera set for bracketing, to press the button
one time and the camera to take automatically the whole bracketing
set.
○ E: BTN > C, E: BTN > C1 — Button confirmation options.
→ E: BTN > C. — MECHA will wait, after any trigger, for confirmation
with the
continue.