Evacuation pressure
Fill diaphragm
Gas flushing pressure
Gas flushing time
Hours of operation
Machine cycles
MCV duration
MCV threshold
Post-evacuation time
Rinsing time, gas
flushing
Sealing time
Sealing time max
Settings - Production
Data
total cycles
Is the pressure to which the film pouch and the chamber are evacu-
ated. The pressure is measured in the chamber.
Evacuation to a pre-determined pressure is suitable for the following
cases:
• Achieving a package result which is different from that of the op-
timum evacuation pressure.
• Packing of products for which the optimum evacuation pressure
is known.
• Packing of the same product which has identical properties.
During this time sealing pressure is applied to the sealing dia-
phragm.
Indicates the pressure until the film pouch is filled with inert gas.
Pressure is measured in the chamber.
Indicates the amount of time for which the film pouch will be filled
with inert gas. Pressure is not influenced by this.
Shows the time the machine has been operating. The counter be-
gins to count as soon as the machine is switched on and can not be
reset.
Counts the number of complete machine cycles. The counter can be
modified and reset. It is used to control the quantities produced.
During this time the set vacuum is maintained during the MCV proc-
ess (Pressure value + threshold).
If the pressure value set here is exceeded during the MCV process,
further evacuation automatically takes place.
This time extends the evacuation process. Through this, the reached
evacuation pressure is lower than the set value. This time begins,
when the set pressure is reached. Suitable for damp products.
During this time the vacuum valve and gas valve are opened simul-
taneously. On one side of the chamber a vacuum is created, on the
other side gas is supplied. The film pouch is thoroughly flushed with
gas. This reduces the residual oxygen content.
During this time the film pouch is sealed. The sealing time depends
on the material and the thickness of the film pouch.
This time determines the maximum value for the sealing time.
Shows all currently set target values.
Shows the completed machine cycles.
03.06.2014
Glossary
87
Need help?
Do you have a question about the C200 and is the answer not in the manual?