Change The Oil In The Vacuum Pump; Drain Oil - multivac C200 Instruction Manual

Chamber machine
Table of Contents

Advertisement

Maintenance
Repair counter-pressure bar
WARNING
64
Clean the profile thread.
– The profile thread should be free of dirt and grease.
Stick the new Teflon tape onto the dry profile thread so that it ad-
heres without bubbles or creases.
7.5

Change the oil in the vacuum pump

7.5.1

Drain oil

Switch off the machine.
Disconnect the machine from the mains electricity.
Allow the machine and vacuum pump to cool down for 1 hour.
Burn hazard!
The surface of the vacuum pump can reach temperatures of over
70 °C during operation.
Touching the vacuum pump can lead to burns.
Before performing any work on the vacuum pump:
Allow the vacuum pump to cool down.
Wear personal protective equipment.
Remove the safety guard on the back of the machine.