multivac C200 Instruction Manual page 31

Chamber machine
Table of Contents

Advertisement

Inert gas (option)
Max. input pressure
Min. input pressure
Inner diameter of supply line
Vacuum pump
Nominal suction capacity
Achievable final pressure approx. 2 mbar
Noise exposure at the workplace
Based on
Measuring instrument
Condition of the machine
A-weighted emission sound-
pressure level at the workplace
L
(DIN ISO 11202, accuracy
pA
class 3) for vacuum pump MRP
20
A-weighted emission sound-
pressure level at the workplace
L
(DIN ISO 11204, accuracy
pA
class 3) for vacuum pump RB
0021
03.06.2014
Technical specifications
2.5 bar
0.7 bar
8 mm
3
• 20 m
/h
3
• 21 m
/h
Machinery Directive
(2006/42/EC)
Sound level meter, IEC 61672- 1,
class 1, error margin +/-1.1 dB
New condition with optimum set-
tings at the time of delivery.
68.8 dB
Measurement inaccuracy: 6 dB
<70 dB