Symptom
Seal seam is uneven
and wavy.
Seal seam is milky.
The excess pouch neck
can only be severed with
difficulty at the sever
seal or it can not be
severed at all.
Odour or smoke.
Machine is very loud.
High oil consumption.
Oil leaks out of machine.
Cause
• The pressure difference be-
tween the chamber and the
outside environment is not
large enough before the seal-
ing process.
• Sealing bar damaged.
• The pressure difference be-
tween the chamber and the
outside environment is not
large enough before the seal-
ing process.
• Teflon tapes on the sealing
bar and counter-pressure bar
are worn.
• Profile thread in the counter-
pressure bar is worn.
• Sealing time is set incorrectly. • Reduce the Sealing time
• Sealing time is set incorrectly. • Increase the value for Sealing
• Air de-oiling element is defec-
tive.
• Oil return valve of vacuum
pump is clogged.
• Air de-oiling element clogged.
• Vacuum pump defective.
• Air de-oiling element clogged.
• Screw plugs or oil sight glass
not tight.
• Vacuum pump defective.
03.06.2014
Troubleshooting
Faults without diagnostic message
Solution
• Reduce Evacuation pressure
value.
• Reduce Gas flushing pressure
value.
• Reduce Gas flushing time
value.
• Replace sealing bar.
• Reduce Evacuation pressure
value.
• Reduce Gas flushing pressure
value.
• Reduce Gas flushing time
value.
• Change the Teflon tapes.
• Repair the counter-pressure
bar.
value. The seal seam should
be clear and transparent.
time in small increments.
• Change air de-oiling element.
• Notify the service.
• Change air de-oiling element.
• Notify the service.
• Change air de-oiling element.
• Tighten screw plugs and oil
sight glass.
• Notify the service.