Operation
Select and set process
44
Call up the "gas flushing" menu (Optional).
Switch on On/off gas flushing.
Set Distribution time.
Set Rinse time.
Press <Gas flushing> key briefly and set value for Gas flushing
pressure.
4.9.2

To set MCV process

Press <Evacuation> key briefly and enter value for Evacuation
pressure.
Info
Do not set an Evacuation pressure value in Automatic.
Press <Evacuation> key briefly again and set the value for Post-
evacuation time to 0 s.
Call up the "evacuation" menu.
Set the value for Distribution time to 0 s.
Select MCV process.
Set MCV threshold.
Set MCV duration.
Call up the "gas flushing" menu (Optional).
Switch off Gas flushing On/Off.
Call up the "sealing" menu.
Switch off Sealing On/Off.
4.10

Setting the sealing

Call up the "sealing" menu.
Switch on On/off sealing.
Set Delayed ventilation.
Set Cooling down.
Press <Sealing> key briefly and set value for Sealing time.
4.11

Entering basic settings

Call up the "basic settings" menu.
Set Fill diaphragm.