multivac C200 Instruction Manual page 52

Chamber machine
Table of Contents

Advertisement

Cleaning
Cleaning recommendations
52
Store empty, new film pouches outside the room in a clean, dry
place during the cleaning procedure.
Remove all waste (e.g. product scraps, film trim) on or around the
machine.
Remove the following components:
– Sloping insert with with support angle.
– Filling plate.
– Sealing bar, see Section 7.3.1 "R
– Insertable counter-pressure bar.
Check chamber lid gasket for dirt or contamination.
If there is dirt or contamination, remove the chamber lid gasket
from the groove.
03.06.2014
EMOVE THE SEALING BAR
".

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C200 and is the answer not in the manual?

Table of Contents

Save PDF