Cleaning
Cleaning recommendations
52
Store empty, new film pouches outside the room in a clean, dry
place during the cleaning procedure.
Remove all waste (e.g. product scraps, film trim) on or around the
machine.
Remove the following components:
– Sloping insert with with support angle.
– Filling plate.
– Sealing bar, see Section 7.3.1 "R
– Insertable counter-pressure bar.
Check chamber lid gasket for dirt or contamination.
If there is dirt or contamination, remove the chamber lid gasket
from the groove.
03.06.2014
EMOVE THE SEALING BAR
".