Troubleshooting
Faults without diagnostic message
Symptom
Pack is leaking.
76
Cause
• Gas flushing pressure is set
too high.
• Gas flushing time is set too
high.
• Pouch neck is clamped by
chamber lid.
• Chamber lid gasket is dirty.
• Insufficient oil quantity or oil in
the vacuum pump is too old.
• Chamber lid gasket is dam-
aged.
• Moist or liquid products give
off steam during the evacua-
tion process.
• Evacuation system is leaking.
• Sealing time is set incorrectly. • Increase the value for Sealing
• Pouch neck is clamped by
chamber lid.
• Seal seam is dirty.
• Film pouch damaged.
• Film pouch not suitable.
• Pouch neck is clamped by
chamber lid.
• Film pouch not suitable.
03.06.2014
Solution
• Reduce Gas flushing pressure
value.
• Reduce Gas flushing time
value.
• Insert the film pouch so that
the pouch neck lies within the
chamber. Cut off the pouch
neck if necessary.
• Clean the chamber lid gasket.
• Refill or replace oil.
• Change chamber lid gasket.
• Abort the evacuation process
with the <Stop> key in case
the chamber lid mists up.
• Pack product with the Auto-
matic function. Set the value
for the Automatic sensitivity.
• Notify the service.
time in small increments.
• Insert the film pouch so that
the pouch neck lies within the
chamber. Cut off the pouch
neck if necessary.
• Keep the inside of the film
pouch in the area of the seal
seam clean.
• Use a new film pouch.
• Use a film pouch suitable for
sealing.
• Insert the film pouch so that
the pouch neck lies within the
chamber.
• Use a film pouch suitable for
sealing.