Handicap lock for reader A or B. This output controls the handicap access
door. Access is granted to cards with handicap privileges.
General purpose output. The general purpose output is for all other types of
outputs, such as turning on a light.
4.8.2
Active state
Outputs require active states. Each output is configured for the active state to
indicate one of the following:
4.8.3
Outputs 1 to 6
Outputs 1 to 6 are relay contact programmable outputs with the following
characteristics. Figure 28 shows a sample connection.
UL Listed TX3-CX Card Access System Installation Manual
50
LT-6906
Copyright 2019
energized
de-energized
normally open (NO)
normally closed (NC) available
125 VAC, 2 A, 0.6 pf (dry contact)
Or
30 VDC, 1 A, 0.6 pf (dry contact)