Hitachi RCI-1.0FSR Service Manual page 255

Hide thumbs Also See for RCI-1.0FSR:
Table of Contents

Advertisement

7 Servicing
RPK-FSR(H)M - Wall mounted
Attaching flat panel.
Insert completely the left and right arm shafts of flat panel into 
the holes along the guide at the front panel. After the flat panel is 
attached completely, insert the catches for air filter to fix it.

For RPK-(2.0-4.0)FSRM
1
Remove the air filter according to the "7.7.1 Removal of the air
2 Hold both sides of flat panel and open it fully.  After the right arm shaft is pushed inward and shafts are removed from 
the front panel, pull the flat panel forward while the right arm shaft is slightly pushed inward.
3 Remove 3 bushes and then 3 screws. Pull the center of the bottom side in the flat panel (2 positions) and the lower 
side of the louver (2 positions) forward to release the catches. Use a slotted screwdriver when the catches are difficult 
to release.
4 Remove the front panel carefully so that it does not touch the horizontal louver attached to the air outlet.  Slightly lift 
the front panel up to release the catches (4 positions) on the upper side of the unit. Then pull the front panel forward 
to remove it.
!
C A U T I O N
Take special care not to be injured by the heat exchanger fins.
?
N O T E
When releasing the catches, snap sound is heard. This is the sound made when the catches are released and so there are no safety
concerns.
Push the shaft 
toward arrow 
direction
Flat panel
245
SMGB0137 rev.0 - 05/2021
Remove this part 
from the hole
Front panel
Flat panel
filter" chapter.
Screw (3 pieces)
Bush (3 pieces)
Guide at 
front panel
Hole
7

Hide quick links:

Advertisement

Table of Contents
loading