VRF AIR CONDITIONER
INDOOR UNIT
(HEAT PUMP)
RCI-1.0FSKDN1Q
RCI-1.5FSKDN1Q
4-Way
RCI-2.0FSKDN1Q
Cassette
RCI-2.3FSKDN1Q
RCI-2.5FSKDN1Q
READ AND UNDERSTAND
THIS MANUAL BEFORE
USING THE HEAT-PUMP
AIR CONDITIONER.
KEEP THIS MANUAL FOR
FUTURE REFERENCE.
RCI-3.0FSKDN1Q
RCI-4.0FSKDN1Q
RCI-5.0FSKDN1Q
RCI-6.0FSKDN1Q
待KATO桑提供
二维码后,将附
在此处。
P01977Q
ORIGINAL INSTRUCTIONS
This manual is exclusively prepared for
R410A indoor unit. Please read this manual
in conjunction with corresponding manual
for outdoor unit.

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi RCI-1.0FSKDN1Q

  • Page 1 VRF AIR CONDITIONER INDOOR UNIT (HEAT PUMP) 待KATO桑提供 二维码后,将附 在此处。 RCI-1.0FSKDN1Q RCI-3.0FSKDN1Q RCI-1.5FSKDN1Q RCI-4.0FSKDN1Q 4-Way RCI-2.0FSKDN1Q RCI-5.0FSKDN1Q Cassette RCI-2.3FSKDN1Q RCI-6.0FSKDN1Q RCI-2.5FSKDN1Q P01977Q READ AND UNDERSTAND THIS MANUAL BEFORE ORIGINAL INSTRUCTIONS USING THE HEAT-PUMP This manual is exclusively prepared for AIR CONDITIONER.
  • Page 2 This declaration becomes invalid, if technical or operational modifications are introduced without the manufacturer's consent. Johnson Controls Hitachi Air Conditioning Europe SAS is authorized to compile technical file or relevant technical documentation. Address : Rue de Lombardie, Parc Aktiland II – 69800 Saint Priest, France...
  • Page 3: General Information

    • The text following this symbol contains information or instructions that HITACHI makes every effort to offer correct, up-to-date may be of use or that require a more thorough explanation. documentation. Despite this, printing errors cannot be controlled •...
  • Page 4: Unit Installation

    • Check space between ceiling and false ceiling is enough as C A U T I O N indicated below. • Do not install the indoor units in a flammable environment to avoid a • Check the ceiling surface is flat for the air panel installation fire or an explosion.
  • Page 5: Refrigerant Piping

     Mounting of Indoor Unit  Ceiling not completed with panels yet Mount the nuts and the washers to the suspension bolts. Put the • Pattern Paper for Installation washer so that the surface with insulation can faces downwards as shown below: Dimension for Opening Dimension for Opening...
  • Page 6: Drain Piping

    Drain trap should be installed next to indoor unit. This trap must • IEC 60335-1 be designed to good practice and be checked with water RCI-1.0FSKDN1Q (charged) and tested for correct flow. Do not tie or clamp the RCI-1.5FSKDN1Q drain pipe and refriger-ant pipe together. RCI-2.0FSKDN1Q 220V~240V RCI-2.3FSKDN1Q...
  • Page 7: Installation

    6. INSTALLATION OF OPTIONAL (7) Once the power cord is damaged, the dealer or the professionals AIR PANEL: P-N23NA2 from designated maintenance department must be contacted in a timely manner for repair and replacement. 6.1 FACTORY-SUPPLIED ACCESSORIES (8) For the installation of power cord, the ground wire must be longer than the current-carrying conductor.
  • Page 8 Indoor unit  Installing Air Panel 1. Remove the cover of the corner pocket (4 portions). Remove Fixing plate (indoor unit) pulling A part toward the arrow direction. Corner panel Long screw False ceiling C A U T I O N •...
  • Page 9 1154122 Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd. Add.: No. 218, Qianwangang Road, Economic and Technological Development Zone, Qingdao, China The Company is committed to continuous product improvement. We reserve the right, therefore, to alter the product information at any time and without prior announcement.